Description
*Price includes crating for HIX-66664*
HIX HG Series Natural Gas Dryer If high production and cost efficiency are driving forces in meeting your drying needs, HIX Premier HG Gas dryers are the solution. Each dryer is configured with an efficient gas burner which works in conjunction with up to 90% recycled air to maintain a consistent oven temperature while consuming less energy. The HG series dryers are designed for all types of screen print inks and virtually any substrate. Its variable air speed controller and digital temperature and belt speed controllers provide total control over the dryer’s heat and cycle speed. With belt widths from 36 inches to 72 inches and oven lengths up to 20 feet, product throughput capacities of up to 500 pieces per hour is achievable making the Premier HG Gas dryer a perfect companion to either manual or automated printers. The removable panels give easy access to air filters minimizing maintenance time to limit overall downtime which eats into profits.
GAS DRYER MODELS | Premier HG-4820 | Premier HG-6020 | ||
EXW Oven Cost | 29395 | 34395 | ||
Stowed inside dedicated container, uncrated | 155 | 155 | ||
Overall Length | 20 feet (609 cm) | 20 feet (609 cm) | ||
inside | 11 feet (335 cm) | 11 feet (335 cm) | ||
outside | 13 feet (396 cm) | 13 feet (396 cm) | ||
Conveyor Infeed | 4 feet (122 cm) | 4 feet (122 cm) | ||
Conveyor Delivery | 3 feet (91 cm) | 3 feet (91 cm) | ||
Fume Hoods – each end | 1 foot (30.5 cm) | 1 foot (30.5 cm) | ||
Frame Width | 61 Inches (155 cm) | 73 Inches (185 cm) | ||
Overall Width - Including Control Box | 69 Inches (175 cm) | 81 Inches (206 cm) | ||
Height (floor to top of exhaust) | 107 Inches (272cm) | 107 Inches (272 cm) | ||
Belt Height from floor | 39 inches (99 cm) | 39 inches (99 cm) | ||
Belt Width | 48 Inches (122 cm) | 60 Inches (152 cm) | ||
Belt Type | TCF (PTFE coated Fiberglass) | TCF (PTFE coated Fiberglass) | ||
Belt Speed | 0 - 17 FPM (0 - 5 m/min) | 0 - 17 FPM (0 - 5 m/min) | ||
Belt Speed Control | Analog Knob 0-10 | Analog Knob 0-10 | ||
Temperature Control | West 6100 Digital (with Hi/Low temp alarm) | West 6100 Digital (with Hi/Low temp alarm) | ||
Oven temperature accuracy | +/- 5°F (2°C) of set point | +/- 5°F (2°C) of set point | ||
Maximum Oven Temperature | 400°F (205°C) | 400°F (205°C) | ||
Minimum Oven Temperature | 250°F (120°C) | 250°F (120°C) | ||
BTU Input Minimum | 100,000 BTU | 100,000 BTU | ||
BTU Input Maximum | 250,000 BTU | 250,000 BTU | ||
Exhaust Airflow | 1,000 CFM – 14” duct (36,400 l/min – 35 cm duct) | 1,000 CFM – 14” duct (36,400 l/min – 35 cm duct) | ||
Exhaust Motor | ½ H.P. direct drive | ½ H.P. direct drive | ||
Recirculating Airflow | 3,500 CFM Fixed | 3,500 CFM Fixed | ||
Recirculating Air Motors | Two 1 H.P. direct drive AC 3-phase motors | Two 1 H.P. direct drive AC 3-phase motors | ||
Air Filters | Combustion Air (1) | Combustion Air (1) | ||
Recirculation Air (1) | Recirculation Air (1) | |||
Back | 18 inches (46 cm) | 18 inches (46 cm) | ||
Ends | 40 inches (102 cm) | 40 inches (102 cm) | ||
Front | 48 inches (122 cm) | 48 inches (122 cm) | ||
Flue to surface | 18 inches (46 cm) | 18 inches (46 cm) | ||
Indicator Lamps | Interlocks Proven | Interlocks Proven | ||
Purging | Purging | |||
Burner On | Burner On | |||
Interlocks | Emergency Stop | Emergency Stop | ||
High Gas Pressure | High Gas Pressure | |||
Low Gas Pressure | Low Gas Pressure | |||
Exhaust Purge Proving | Exhaust Purge Proving | |||
Recirculation Proving | Recirculation Proving | |||
Flameguard (flame proving) | Combustion Air Proving | Combustion Air Proving | ||
High Temp Limit | High Temp Limit | |||
Safety Standards | Built to UL-795 | Built to UL-795 | ||
Electrical Requirements | 220V, 3-Ph, 10 Amps | 220V, 3-Ph, 10 Amps | ||
60 Hz | 60 Hz | |||
Minimum Circuit Amps | 20 Amps | 20 Amps | ||
Maximum Fuse Size | 20 Amps | 20 Amps | ||
Gas Type Requirements | Natural Gas | Natural Gas | ||
Gas Pressure Requirements | 6.0" - 10.0" Water Column | 6.0" - 10.0" Water Column | ||
Gas Service Inlet | 1/2” NPT | 1/2” NPT | ||
Gas Pressure Propane | 0.5 PSI / 34mbar | 0.5 PSI / 34mbar | ||
Electric | 2.5kW | 2.5kW | ||
Natural Gas | 0.12 MCF/H | 0.13 MCF/H | ||
Propane | .052 MCF/H | .056 MCF/H | ||
in US$ (electric @ $0.10/kWh; gas @ $6.50/MCF) | 1.03 | 1.15 |