Support
Machine type
Brand
BBC Forced Air and Aeolus Conveyor DTG Dryers

BBC Forced Air and Aeolus dryer settings: zone temperatures, conveyor time and fixes when it won't hold heat

✓ Reviewed by Jason KimUpdated 2 min readFits: BBC Forced Air 24 in and 36 in · Aeolus
Short answer

BBC's suggested Forced Air starting point for digital ink-jet (DTG) prints is Zone 1 at 750°F, Zone 2 at 550°F and 2:00 on the conveyor. The display shows heating element temperature, not air or shirt temperature, so wash test and change one setting at a time. If the controller reads OPEN, the thermocouple has failed or come loose; if heat never rises or won't stop rising, the solid state relay may have failed.

Start-up

  1. Forced Air

    Flip the Conveyor switch on, then the Heat switch. Set each zone's set point with the arrow keys on its temperature controller and press enter. Set the conveyor with the + and - keys, one digit at a time.

  2. Aeolus

    Turn the power disconnect on and make sure the E-STOP is out. Press START to power the heaters, conveyor, blowers and fans. Put the conveyor switch in RUN and set the conveyor time, shown as MM:SS through the tunnel.

  3. Let it settle

    When the zones reach their set points, wait another 5 minutes before running product.

The conveyor belt must be moving whenever the heat is on, or the belt can be damaged. On the Aeolus, use SHUT-DOWN for a normal stop: the heaters go off and the conveyor and blowers keep running 10 minutes to cool them. E-STOP stops everything at once and the heaters stay hot, so save it for emergencies. Twist it counterclockwise to reset.

BBC starting settings, Forced Air dryer

Ink Zone 1 Zone 2 Conveyor
Plastisol 900°F 700°F 0:30
Screen-printed water-based 800°F 600°F 1:00
Digital ink-jet (DTG) 750°F 550°F 2:00

BBC starting settings, Aeolus

Time in tunnel Zone 1 Zone 2
0:30 860 to 870°F 740 to 780°F
0:45 860 to 870°F 665 to 690°F
1:30 860 to 870°F 540 to 590°F
3:00 760 to 770°F 490 to 540°F

Every Aeolus is tested at BBC before shipping, and the maximum temperatures reached are recorded in its manual. If your dryer tops out lower in your shop, because of voltage, room conditions or a sensor that moved in shipping, your working settings will be lower too.

Finding your setting

  • Scorching means too hot. Not fully cured means turn it up.
  • Change only one setting at a time, then let the oven soak for a few minutes before the next test.
  • Wash the test garments. BBC calls the wash test the definitive check of your settings.
  • For DTG, follow your ink and pretreat maker's cure temperature, and check the shirt surface with a heat gun as it exits.

Won't hold temperature

BBC expects the oven to hold within 5 to 10°F of the set point.

What you see Likely cause What to do
Runs cooler than usual everywhere Low supply voltage Have an electrician confirm the voltage at the dryer
Temperature swings Drafts from doors, fans or air conditioning Block drafts. Never point a fan at the oven
Controller reads OPEN Thermocouple failed or disconnected Contact us for a replacement thermocouple
Never heats, or heats past the set point and keeps going Solid state relay failed open or closed Shut the heat off and contact us

Thermocouple, relay and terminal work happens inside the control panel at line voltage. BBC requires the power to be locked out first, and it should be done by an electrician or technician. Text us a photo or short video at (562) 609-4996.

Common questions

Why are the temperatures so high?

The controller shows the temperature of the heating element itself, not the air in the chamber or the shirt. That is why the settings are in the hundreds of degrees.

Why is Zone 1 hotter than Zone 2?

Zone 1 brings the garment up to cure temperature quickly; the cooler Zone 2 holds it there longer without scorching, curing deeper layers of ink.

Can I turn off the forced air?

No. The blower also insulates the oven and keeps its outside cool, so it always runs.

How long after a change before I run shirts?

Once the set point is reached, BBC says to allow another 5 minutes for the oven to settle. Do the same after every temperature change.

The conveyor stopped. What do I check?

On the Forced Air, check the fuse on the back of the control panel and push it to reset. On the Aeolus, check the circuit breaker on the control panel. If it trips again, stop and contact us.

Did this fix it?