Vastex EconoRed II, III and VI Infrared Conveyor Dryers

Vastex EconoRed II, III and VI Infrared Conveyor Dryers support

Covers: EconoRed II · EconoRed III · EconoRed VI

The Vastex EconoRed II, III and VI are high production infrared conveyor dryers with a digital temperature controller, adjustable heater height, variable belt speed and an exhaust stack. They are assembled and run the same way: the III adds a third heater and the VI adds a second chamber. Start here for setup, cure settings, belt tracking, the maintenance schedule and controller error codes.

Vastex EconoRed II infrared conveyor dryer with 54 inch belt

Setup & first print

Daily & weekly maintenance

Troubleshooting

Error messages

Techniques & settings

Manuals & downloads

Watch Vastex's video: EconoRed settings to cure plastisol

Embedded from the manufacturer's official channel.

About the Vastex EconoRed II, III and VI Infrared Conveyor Dryers

Every EconoRed uses medium wave infrared heaters controlled by a digital PID temperature controller and a Type J thermocouple mounted under the first heater. A 130 V DC gear motor drives a Teflon coated fiberglass belt through a #35 chain, and an 8 in exhaust stack with an adjustable damper pulls fumes out of the chamber. The belt comes in 30 in and 54 in widths, and Vastex also builds a 78 in wide version.

The three models

Model Difference
EconoRed II Base model
EconoRed III Third heater, chamber 18 in longer
EconoRed VI Second chamber, crated separately and bolted on

Maintenance at a glance

How often What to do
Weekly Check both fresh air filters and the belt tracking and condition
Every 3 months Oil the drive chain, clean the rear exhaust hood intake if fitted, have the control box connections checked
Every 6 months Replace the fresh air filters, anti-seize the lead screws, clean lint from the upper air chamber
Yearly Remove and clean the exhaust ducting

Where to put it

Vastex requires a room between 40°F and 100°F with no more than 80% humidity, and warns that ignoring this can damage the dryer and void the warranty. At 70°F it can run up to 18 hours, then needs 30 minutes off; the hotter the room, the shorter the run time. A licensed electrician must install it, and the exhaust must vent outside with no more than 10% loss of airflow.