Support
Machine type
Brand
Vastex EconoRed II, III and VI Infrared Conveyor Dryers

Vastex EconoRed troubleshooting: no heat, temperature swings, belt stopped and controller error codes (SbEr, AtEr)

✓ Reviewed by Jason KimUpdated 2 min readFits: EconoRed II · EconoRed III · EconoRed VI (TEC-9400 controller from November 2020, TEC-9090 before)
Short answer

Start with the pilot lights. The green control output light and red relay light should cycle together, and each heater has a white light. No power light means a power supply, breaker or fuse problem; a power light but no heat points to fuses, the heater or a relay. SbEr on the controller means the Type J sensor has failed: the controller drops into manual mode so you can keep running while a replacement is ordered.

Turn off and lock out power at the main disconnect before opening the control box. The red power light must be off. Any test with power on must be done by a qualified electrician. Shutting off the front power switch alone does not make the box safe.

Read the lights first

Light What it tells you
Red power Main power switch is on
Green output Controller is calling for heat. Should cycle on and off.
Red relay Relay is sending power. Should cycle with the green light.
White heater One per heater. Power is reaching that heater.
Blue fan One per fan. Power is reaching the exhaust fan.

Match your symptom

Symptom What to check
No heat, power light off Incoming power, the shop disconnect, breakers and fuses, the power cord and its connections
No heat, power light on A burned out heater, the system fuses in the control box, and which pilot lights are on
Too hot or too cold Pilot lights: a relay can stick on or off
Temperature swings Sensor position, clean sensor connections, drafts or fans in the shop
Belt stopped or erratic Motor plug, sprocket and chain, obstructions in the belt path, belt tension

Fuses and relays are inside the control box, so those checks are for an electrician. The chain, belt path and tension you can check yourself with power off; see our maintenance guide.

Controller error codes

Code Meaning What to do
SbEr Sensor break Replace the Type J sensor. Run in manual mode meanwhile.
LLEr, HLEr Reading outside the low or high range setting Contact us. The range values need resetting.
AHEr Analog module damage Module or controller replacement. Look for voltage spikes.
AtEr Auto tune failed Repeat the auto tune. If it fails again, contact us.
oPEr Manual mode not allowed Contact us
C5Er Memory values changed Contact us to reconfigure the settings

Run in manual mode after SbEr

When the sensor fails, the display shows SbEr, the output indicator flashes MAN and H0.00 appears below. Use the up or down arrow to set the percentage of time the heaters are on (80.0 means on 80% of the time). You can keep producing like this, checking your ink temperature closely, until the new sensor is in.

Auto tune

Do this if your shop is below 240 V, or after a new controller, sensor or heaters. Start with the heaters below 300°F. Enter the set point first: 700°F for 240 V class units (500°F for 120 V units).

  1. Open auto tune

    Hold the scroll button until A-T shows, then release.

  2. Start it

    Hold scroll again until the output indicator flashes TUNE, then release. PASS appears; press scroll once to clear it.

  3. Wait

    TUNE keeps flashing until the process ends. It can take up to 30 minutes.

If the dryer smells hot, smokes heavily, vibrates or makes new noises, turn it off and contact us. Text a photo of the control panel with the lights on to (562) 609-4996.

Common questions

The belt runs but there's no heat. What first?

Check the heat switch is on and watch the lights. If the green light cycles but the red relay light doesn't, the relay is the suspect. If both cycle but a white heater light stays off, that heater may be out. Internal checks with power on are for a qualified electrician.

What does SbEr mean?

Sensor break. The Type J thermocouple has failed. The controller switches to manual mode; set a percentage of on time with the arrows and keep printing while you get a new sensor.

When do I need to auto tune?

Vastex tunes every dryer at the factory. Auto tune again if your supply is below 240 V (for example 208 V), or after replacing the controller, the sensor or the heaters.

How do I switch between Fahrenheit and Celsius?

Hold the scroll button until SEt shows, press scroll 5 times to reach UNIt, then use the down arrow for °C or the up arrow for °F.

The temperature keeps swinging.

Check the sensor position and connections, and stop drafts or fans blowing through the chamber.

Sources
Did this fix it?