Vastex LittleRed X-Series Infrared Conveyor Dryers

Vastex LittleRed X-Series Infrared Conveyor Dryers support

Covers: LittleRed X1 · X1D · X2 · X2D · X3 · X3D

LittleRed dryers cure prints with infrared heaters over a moving mesh belt. Cure depends on three things you control: heater set point, heater height, and belt speed (time in the chamber). The D models add a boost zone at the entrance for DTG and other long cures. Always keep the belt moving while the heaters are above 300°F.

Vastex LittleRed X1-D infrared conveyor dryer

Setup & first print

Daily & weekly maintenance

Troubleshooting

Error messages

Techniques & settings

Warranty & service plans

Manuals & downloads

Watch Vastex's video: Introduction of the LittleRed X1-D DTG dryer

More videos

Brother GTX curing on a Vastex LittleRed X3-D
The importance of using a donut probe

Embedded from the manufacturer's official channel.

About the Vastex LittleRed X-Series Infrared Conveyor Dryers

The LittleRed is a closed-loop infrared dryer: a sensor just under the heater reports to a digital controller, which switches the heater through a relay. Because the sensor sits right at the heater, the set point is far hotter than the garment ever gets. The X1D runs the front part of its heater at full power as a boost to preheat garments on entry. The X2D and X3D have separate BOOST and MAIN zones, and BOOST must be set equal to or higher than MAIN.

Care at a glance

How often What to do
Every shift Run the shutdown procedure: heat off, let it cool to 300°F with the belt running, then system switch off and main disconnect off
Monthly (busy shops) Disconnect the ducting and clean around the top exhaust fan
Every 2 to 3 months Clean the exhaust blower
Every 3 months With power off at the disconnect, have all electrical connections checked and tightened
Quarterly to every 6 months Remove the lid and inner panel and vacuum lint from the chamber and the tops of the heaters
As needed Check the drive chain (no more than 1/4 in of play) and belt tracking

Where to put it

Vastex rates the dryer for rooms between 40 and 105°F. It must be wired by a licensed electrician to a dedicated breaker with a main disconnect, and no extension cords. Duct the exhaust with a flexible section so you can still open it for cleaning. If your shop voltage is below 240 V (208 V, for example), the controller needs an auto-tune.