Support
Machine type
Brand
Vastex LittleRed X-Series Infrared Conveyor Dryers

Vastex LittleRed dryer cleaning: exhaust fan, lint in the chamber, heater tops and drive chain

✓ Reviewed by Jason KimUpdated 3 min readFits: LittleRed X1 · X1D · X2 · X2D · X3 · X3D
Short answer

Vastex says to clean around the LittleRed's top exhaust fan monthly and to remove the exhaust lid and inner panel quarterly to vacuum lint from the chamber and the tops of the heaters. A blocked exhaust lets heat build up in the chamber. Always cool the heater with the belt running, then lock out power at the disconnect before you open anything.

Lint from garments collects wherever hot air flows, and a clogged exhaust lets heat build up in the chamber. Vastex's intervals below are for busy shops. Stretch them if you run the dryer lightly, but check by eye.

Before any cleaning or adjustment: turn the heat off and let the belt run until the heater is at 300°F or below, then switch off at the main disconnect (or unplug) and lock it out. The red Power light must be off. The heaters run near 1,000°F, so let them cool fully before you reach inside.

Cleaning schedule

How often What to clean
Monthly (about 20 production days) Around the top exhaust fan
Every 2 to 3 months Exhaust blower on rear-exhaust models
Quarterly (about 60 production days) Whole exhaust, chamber and the tops of the heaters
Every 3 months Electrical connections checked and tightened
As needed Drive chain: check, adjust and lubricate

Monthly: around the exhaust fan

  1. Disconnect the ducting

    Pull the duct off the exhaust box. This is why Vastex wants a flexible section in the duct run.

  2. Open the exhaust box

    Remove the 12 sheet metal screws on top of the exhaust box.

  3. Clean and close

    Vacuum and wipe lint from next to and around the fan. Refit the cover and screws and reconnect the duct.

Quarterly: exhaust, chamber and heaters

  1. Remove the exhaust with its lid

    Disconnect the ducting. With a 1/4 in (5 mm) nut driver, remove the sheet metal screws on the lid that carries the exhaust. On many models that is the rear lid. Lift the lid off carefully and set it aside without pulling on any wiring.

  2. Clean the chamber

    Vacuum and wipe the whole exposed chamber and everything you can reach.

  3. Remove the inner panel

    Take out the inner panel's sheet metal screws, again watching the wiring, and slide the panel out.

  4. Clean the heater tops

    Vacuum and wipe lint off the tops of the heaters and all accessible areas. Don't touch or press on the heater faces.

  5. Reassemble

    Refit the inner panel, lid and exhaust, taking care not to pull or pinch any wire, and reconnect the duct.

Older rear-exhaust models

Remove the rear exhaust scoop and clean the filter under it. Clean the exhaust blower at the back every 2 to 3 months: it sits behind the exhaust hood cover, held by black #8 machine screws. Every six months, take off the top cover and clean around the heater.

Drive chain

  1. Remove the chain guard

    Undo the two black sheet metal screws at the top of the guard at the rear of the conveyor.

  2. Set the tension

    Loosen the three control assembly mounting screws. The drive plate is slotted, so the whole assembly slides to tighten or loosen the chain. Set it so the chain moves up and down about 1/4 in. Don't overtighten: that damages the bearings.

  3. Check the set screws

    Make sure the set screws on both sprockets are tight, using a 1/8 in Allen key. Lubricate the chain if it is dry, then refit the guard. Never run the dryer with the chain guard off.

Electrical connections

Heating and cooling slowly loosens connections. Every three months, with power off at the disconnect, Vastex says every connection point should be inspected and tightened. Any test that needs power on must be done by a qualified electrician.

Exhaust warning lights

On models with Exhaust System Fault lights (such as the X3D-78), the lights flicker at start-up while the fans spin up, then must go out. If one stays lit, the exhaust is probably blocked or a fan has failed. Turn the heat off, keep the belt running until it cools, and check the duct and fan. Text us a photo or short video at (562) 609-4996 if it stays on after cleaning.

Common questions

How often should I clean the LittleRed's exhaust?

Vastex says monthly (about 20 production days) around the fan, and quarterly (about 60 production days) for the whole exhaust, chamber and heater tops, in a busy shop.

Can I clean it while it is hot?

No. Turn the heat off, keep the belt moving until the heater is at 300°F or below, then switch off and lock out power at the disconnect.

An Exhaust System Fault light is on.

The exhaust is probably blocked or a fan has failed. Cool the dryer down, then check the duct and fan. Contact us if the light stays on.

How tight should the drive chain be?

Vastex says about 1/4 in of up and down movement. Too tight wears the bearings.

Does my dryer have a top exhaust?

Vastex made the powered exhaust standard on LittleRed dryers built after May 2020. Older units have a rear exhaust hood with a scoop and filter.

Did this fix it?