Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Vastex LittleRed dryer cleaning: exhaust fan, lint in the chamber, heater tops and drive chain
Vastex says to clean around the LittleRed's top exhaust fan monthly and to remove the exhaust lid and inner panel quarterly to vacuum lint from the chamber and the tops of the heaters. A blocked exhaust lets heat build up in the chamber. Always cool the heater with the belt running, then lock out power at the disconnect before you open anything.
Lint from garments collects wherever hot air flows, and a clogged exhaust lets heat build up in the chamber. Vastex's intervals below are for busy shops. Stretch them if you run the dryer lightly, but check by eye.
Before any cleaning or adjustment: turn the heat off and let the belt run until the heater is at 300°F or below, then switch off at the main disconnect (or unplug) and lock it out. The red Power light must be off. The heaters run near 1,000°F, so let them cool fully before you reach inside.
Cleaning schedule
| How often | What to clean |
|---|---|
| Monthly (about 20 production days) | Around the top exhaust fan |
| Every 2 to 3 months | Exhaust blower on rear-exhaust models |
| Quarterly (about 60 production days) | Whole exhaust, chamber and the tops of the heaters |
| Every 3 months | Electrical connections checked and tightened |
| As needed | Drive chain: check, adjust and lubricate |
Monthly: around the exhaust fan
-
Disconnect the ducting
Pull the duct off the exhaust box. This is why Vastex wants a flexible section in the duct run.
-
Open the exhaust box
Remove the 12 sheet metal screws on top of the exhaust box.
-
Clean and close
Vacuum and wipe lint from next to and around the fan. Refit the cover and screws and reconnect the duct.
Quarterly: exhaust, chamber and heaters
-
Remove the exhaust with its lid
Disconnect the ducting. With a 1/4 in (5 mm) nut driver, remove the sheet metal screws on the lid that carries the exhaust. On many models that is the rear lid. Lift the lid off carefully and set it aside without pulling on any wiring.
-
Clean the chamber
Vacuum and wipe the whole exposed chamber and everything you can reach.
-
Remove the inner panel
Take out the inner panel's sheet metal screws, again watching the wiring, and slide the panel out.
-
Clean the heater tops
Vacuum and wipe lint off the tops of the heaters and all accessible areas. Don't touch or press on the heater faces.
-
Reassemble
Refit the inner panel, lid and exhaust, taking care not to pull or pinch any wire, and reconnect the duct.
Older rear-exhaust models
Remove the rear exhaust scoop and clean the filter under it. Clean the exhaust blower at the back every 2 to 3 months: it sits behind the exhaust hood cover, held by black #8 machine screws. Every six months, take off the top cover and clean around the heater.
Drive chain
-
Remove the chain guard
Undo the two black sheet metal screws at the top of the guard at the rear of the conveyor.
-
Set the tension
Loosen the three control assembly mounting screws. The drive plate is slotted, so the whole assembly slides to tighten or loosen the chain. Set it so the chain moves up and down about 1/4 in. Don't overtighten: that damages the bearings.
-
Check the set screws
Make sure the set screws on both sprockets are tight, using a 1/8 in Allen key. Lubricate the chain if it is dry, then refit the guard. Never run the dryer with the chain guard off.
Electrical connections
Heating and cooling slowly loosens connections. Every three months, with power off at the disconnect, Vastex says every connection point should be inspected and tightened. Any test that needs power on must be done by a qualified electrician.
Exhaust warning lights
On models with Exhaust System Fault lights (such as the X3D-78), the lights flicker at start-up while the fans spin up, then must go out. If one stays lit, the exhaust is probably blocked or a fan has failed. Turn the heat off, keep the belt running until it cools, and check the duct and fan. Text us a photo or short video at (562) 609-4996 if it stays on after cleaning.
Common questions
How often should I clean the LittleRed's exhaust?
Vastex says monthly (about 20 production days) around the fan, and quarterly (about 60 production days) for the whole exhaust, chamber and heater tops, in a busy shop.
Can I clean it while it is hot?
No. Turn the heat off, keep the belt moving until the heater is at 300°F or below, then switch off and lock out power at the disconnect.
An Exhaust System Fault light is on.
The exhaust is probably blocked or a fan has failed. Cool the dryer down, then check the duct and fan. Contact us if the light stays on.
How tight should the drive chain be?
Vastex says about 1/4 in of up and down movement. Too tight wears the bearings.
Does my dryer have a top exhaust?
Vastex made the powered exhaust standard on LittleRed dryers built after May 2020. Older units have a rear exhaust hood with a scoop and filter.
- Vastex LittleRed-X Series assembly, operating and maintenance instructions, doc 01-28-001
- Vastex LittleRed X1D operation manual
- AA support requests about Vastex dryers, 2024 to 2026