✓ Reviewed by Jason KimUpdated 3 min readFits: LittleRed X1 · X1D · X2 · X2D · X3 · X3D
Short answer

When the belt runs but the dryer won't heat, the pilot lights tell you where the heat stops: the controller output light, then the red relay light, then the white heater light. If the Power light is off, look at the shop disconnect, breakers and fuses. Belt drifting is corrected at the aligner roller, half a turn at a time with the belt moving. A controller showing SbEr has lost its sensor and can run in manual mode until the sensor is replaced.

Turn power off at the external disconnect (the red Power light must be out) before opening any part of the dryer. The heaters run near 1,000°F. Any testing with power on should be done by a qualified electrician.

Match your symptom

What you see What to check Go to
No heat, Power light off Shop disconnect, breakers, fuses, power cord Step 1
No heat, Power light on, belt running Control fuses, then the pilot light chain Steps 2 and 3
Heat too high or too low Pilot lights (a relay can stick on or off) Step 3
Temperature fluctuates Sensor location and connections, drafts Step 4
Controller shows an error code See the code table Step 5
Belt stopped or erratic Motor plug, chain and sprockets, obstructions, belt tension Step 6
Belt drifts to one side or slips Belt tracking and tension Step 7

Step by step

  1. Power light off

    Check the shop disconnect, the breaker feeding the dryer, and the power cord and its connections.

  2. Power light on, no heat: fuses

    The control circuit fuses are on the face of the control panel (inside the control box on older models). Check them against the fuse specs on your wiring diagram.

  3. Follow the pilot lights

    With the heat switch on: the control output light should cycle on and off as the controller calls for heat. The red relay output light should cycle with it, which shows the relay is switching. The white heater light (one per heater) shows electricity is flowing to that heater. Where the chain stops is where the fault is. Note what each light does and contact us; a heater that has burned out needs replacing.

  4. Temperature fluctuates

    Check the sensor is in its shield under the heater, clean its connections, and get rid of drafts through the chamber.

  5. Read the error code

    Code Meaning Fix
    SbEr Sensor break Replace the sensor. Use manual mode meanwhile
    LLEr / HLEr Reading beyond the low or high range set point Contact us to re-adjust
    AHEr Analog module damage Module replacement. Look for voltage spikes
    AtEr Auto-tune didn't run correctly Repeat auto-tune
    CSEr Memory values changed Controller settings need re-entering. Contact us

    In manual mode after SbEr, the display shows H0.00 and MAN flashes. Use the arrows to set the percentage of time the heater is on (80.0 means on 80% of the time) and keep a close eye on cure.

  6. Belt stopped or erratic

    Check the plug at the motor power cord, the sprockets and chain, anything blocking the belt path, and belt tension. The drive chain behind the chain guard should have no more than 1/4 in of play; it's adjusted by loosening the four motor mount bolts. Don't over-tighten it, and always refit the chain guard. A technician can check for 90 V DC at the motor plug.

  7. Belt tracking and slipping

    Adjust at the aligner roller with the belt moving, in small steps, and never leave it running unattended while you do. If the belt slips, raise both sides of the aligner roller equally by turning the aligner bolts clockwise. If the belt runs to the left, raise the left side; if it runs right, raise the right side, half a turn at a time. Never tighten the nut on the aligner bolt. Aim for 1 to 2 in of sag on the bottom run.

Auto-tune the controller

Needed when shop voltage isn't 240 V, or after replacing the controller, sensor or heaters. Let the heater cool below 300°F. Enter the set point first: 500°F for 120 V units, 700°F for all others. Then press and hold the scroll button until A-T shows and release; hold it again until TUNE flashes and release. When PASS appears, press scroll once. TUNE keeps flashing until it's done, which can take up to 30 minutes. Controllers changed model around November 2020, so if your screen doesn't match, contact us.

Common questions

I replaced the relay and it still won't heat.

Watch the lights with the heat switch on. If the red relay light cycles but the white heater light doesn't come on, power isn't reaching the heater: suspect a heater or its wiring. If the controller output light isn't cycling, the problem is before the relay. Text us what each light is doing.

What does SbEr mean?

Sensor break. The controller can't read the sensor under the heater and drops into manual mode. Replace the sensor. Until then you can set a percentage of on-time in manual mode and keep running.

When do I need to auto-tune the controller?

Vastex auto-tunes at the factory. Do it yourself if your shop voltage isn't 240 V (208 V, for example), or after replacing the controller, sensor or heaters.

How tight should the belt be?

Vastex wants 1 to 2 in of sag on the bottom run. You should be able to stop the rear drive pulley with moderate force on the belt, so the belt slips before the motor is damaged.

My temperature swings up and down.

Check the sensor location, clean the sensor connections, and stop drafts from fans, doors or AC blowing through the dryer.