Support
Machine type
Brand
Mimaki TxF330-800

Mimaki TxF330-800 daily and weekly maintenance: wiper, cap, carriage, NCU and idle-week storage

✓ Reviewed by Jason KimUpdated 3 min readFits: TxF330-800
Short answer

Before work each day, clean the wiper and bracket, the cap rubber and the underside of the carriage with a cleaning stick and maintenance liquid. Once a week add the NCU, DAS sensor, ink discharge channel, sensors, platen and covers, and once a month the washing tray. Shake white ink 40 times daily and colors 20 times weekly. If it will sit for a week or more, run Custody Wash and leave the main power on.

Mimaki's schedule is simple: three items before work every day, a longer list once a week, and one monthly job. All of it starts from the same menu, and none of it needs tools beyond cleaning sticks, maintenance liquid, a soft cloth, gloves and safety glasses.

Never touch the nozzle surface. Don't let water or alcohol near it, don't use IPA, acetone or thinner anywhere on the machine, don't use an air blower, and don't move the carriage by hand. Leave no cleaning stick fibers behind.

Before work every day

  1. Shake the white ink

    Shake each white cartridge 40 times, slowly left to right, when the printer has been on for more than 24 hours or the display asks. After 3 or more days, shake it 100 times. Shake each color cartridge 20 times once a week before work.

  2. Bring the carriage out

    On the LOCAL screen select MENU > Maintenance, then Station Maint. > Carriage Out > Move To Platen Right End and press ENTER. Open the front cover.

  3. Clean the wiper

    Press the lugs on both sides of the wiper bracket and pull the wiper out. Wipe ink and dust off the wiper and bracket with a cleaning stick moistened with maintenance liquid, then wipe the liquid off. Clean inside the groove of the wiper holder and push the wiper back in. Replace a wiper that is dirty or warped.

  4. Clean the cap rubber

    Wipe the cap rubber the same way and make sure no liquid is left. Check that the cap slider isn't tilted. If it is, move the slider block left or right to straighten it. Close the cover and press ENTER.

  5. Clean under the carriage

    Select Station Maint. > Carriage Out > Move To Maint. Space and open the maintenance covers. With a cleaning stick and maintenance liquid, clean the sides of the head and all around the nozzle plate, not the nozzles. Close the covers and press ENTER.

At the end of the week

Repeat the daily items, then add these:

  • NCU (the nozzle check sensor): carriage to the platen right end, then clean it with a moistened cleaning stick, inserting it only as far as the line shown in the manual. A dirty NCU makes the automatic nozzle check unreliable.
  • DAS sensor under the carriage: carriage to the maintenance space, wipe with a cotton swab or soft cloth.
  • Ink discharge channel: select Station Maint. > Pump tube cleaning. The cap fills with maintenance liquid (the front cover must be closed). Open the cover and check it's full. If not, top it up with a syringe until it almost overflows, close the cover and press ENTER.
  • Media sensors on the rear cover and under the carriage, with a cotton swab or soft cloth.
  • Media holders, platen and outer covers: for the holders and platen, turn off and unplug first. Wipe with a soft cloth in diluted neutral detergent, well wrung out. Clear dust from the media holder and cutting grooves.
  • Waste ink: check the level in the waste ink tank.

Once a month: the washing tray

Select Station Maint. > Wiper maintenance > wash tray cleaning. Open the front cover, soak up the liquid in the tray with a cloth, and loosen any dried ink at the bottom with a moistened cleaning stick. Close the cover and press ENTER, and the tray refills. If the maintenance liquid cartridge is empty, fill it by syringe with about 25 cc, 9 to 10 mm below the Tray Full line.

Leaving it idle for a week or more

  1. Check the ink first

    If Near End or Ink End is showing, replace the ink. The wash draws ink and liquid and stops on an error.

  2. Run Custody Wash

    Select Station Maint. > Custody Wash. Clean the wiper and bracket and press ENTER, then the cap rubber, then close the cover and press ENTER. Check the cap is full of maintenance liquid (top up by syringe if not), close the cover, set the soak time and press ENTER. When the nozzle wash ends, check the cap again and press ENTER to wash the pump tube.

  3. Park it properly

    Leave the main power on. Take the film off the platen and raise the clamp lever so the pinch rollers don't flatten. If Check Waste Ink Tank shows, deal with it before you leave.

Common questions

Can I use alcohol or water on the head area?

No. Mimaki says water or alcohol must never touch the nozzle surface, and organic solvents such as IPA or acetone can damage the machine. Use Mimaki maintenance liquid on a cleaning stick.

Can I use cotton swabs?

Not around the head or carriage, because fibers can end up on the nozzles. Mimaki uses them only for the DAS sensor and the media sensors.

The display says No maintenance for some days. What clears it?

Do the maintenance, using Station Maint. > Carriage Out. Running carriage out clears the message.

How hard do I shake the cartridges?

Slowly, left to right. Shaking too hard can damage the ink pack inside and cause a leak. If a cartridge has been opened, hold a paper towel over the opening and side gap while you shake.

Should I turn the main power off for a long break?

No. With the main power off the automatic anti-clog and channel cleaning can't run. Turn it off only with the END/POWER key.

Did this fix it?