✓ Reviewed by Jason KimUpdated 2 min readFits: PonyXprs (Pony dryer PD-2004, PD-2006, PD-2407)
Short answer

Brown's starting point for the Pony dryer is about 60 seconds in the chamber with the heaters on high and set about 3 in above the garment. Always confirm the cure with a stretch test and heat tapes. To shut down, turn the heaters off and let the dryer cool for about 10 minutes before you switch off main power. Track the belt on high speed with the heat off, using the knobs on the end of the conveyor frame.

The control panel

Control What it does
Main power Turns the dryer on and off
Belt speed Sets how fast the belt moves through the chamber
Pilot light On when a heater is on
Heater switch One on the PD-2004. Two on the PD-2006 and PD-2407; the right hand switch is the front heater.
Breakers Protect the circuits

Start-up

  1. Main power on

    Turn the main power switch on.

  2. Set the belt

    Adjust the belt speed dial so a garment spends about 60 seconds in the chamber. Time it with a stopwatch.

  3. Heaters on

    Turn on the heater switch or switches. Brown recommends running them on high for most jobs.

  4. Set the height

    Use the handles on the ends of the tunnel to raise or lower the heater rack so the heaters sit about 3 in above the garment.

  5. Forced air

    Turn the forced air switch on if your job needs it.

  6. Check the cure

    Do a stretch or crack test on every job and check garment temperature with heat tapes.

Brown makes the user responsible for confirming cure. Check prints regularly during production, not just at the start.

Shutdown

  1. Heaters off

    Turn the heaters off and let the dryer cool for about 10 minutes.

  2. Main power off

    Then turn the main power off.

Belt tension

The knobs on the ends of the pulley take-up plates set tension. Use just enough that the belt doesn't slip on the pulley. Too much shortens the life of both the belt and the belt motor. All conveyor belts stretch, so check tension periodically.

Belt tracking

  1. Heat off, belt fast

    Run the belt on high speed with the heaters off and watch which way it drifts.

  2. Steer it

    Use the knobs on the end of the conveyor frame. Adding tension on one side moves the belt toward the opposite side. Reducing tension on one side moves the belt toward that side. Make small changes and let the belt run a few turns between them.

  3. Recheck hot

    The belt may need a small correction once the dryer is at full temperature, and again as the belt stretches with wear.

When cure changes

If prints that used to cure start failing a stretch test, check that the heater pilot light is on, that the heater rack has not been moved, and that belt speed has not been changed. Slow the belt or lower the heaters a little and test again, one change at a time. If heat seems low, see our troubleshooting guide.

Drive chain

Check the belt drive chain for lint now and then. If it's heavy, turn off power to the dryer and remove the lint with a stiff brush. If the belt still slips or wanders, text us a short video at (562) 609-4996.

Watch Brown's video: how to set up a PonyXprs

Embedded from the manufacturer's official channel.

Common questions

What settings does Brown recommend?

Belt speed for about 60 seconds in the chamber, heaters on high for most jobs, heaters about 3 in from the garment. Then check the cure.

How tight should the belt be?

Just enough that it doesn't slip on the pulley. Extra tension shortens the life of the belt and the belt motor.

The belt drifts to one side.

More tension on one side pushes the belt toward the other side; less tension on a side lets it move toward that side. Adjust with the dryer cold and the belt on high speed.

Which heater switch is which on the two-heater models?

On the PD-2006 and PD-2407 the right hand switch controls the front heater.

How do I know it's cured?

Brown says to check every job with a stretch or crack test and to check garment temperature with heat tapes.

Did this fix it?