✓ Reviewed by Jason KimUpdated 3 min readFits: Auto Open Cap Press (STXC)
Short answer

Remove the packaging bolt on top, plug into a full 10 amp grounded circuit and switch on. Press Mode once to set temperature (176 to 430°F), a second time for Time #1, a third time for Time #2 and a fourth time to go back to print mode. Turn the knob clockwise for more pressure and read the 0 to 9 number on the display with the handle locked down.

The Auto Open Cap Press is a small clamshell press with a curved heat platen for hats. It runs from four controls on the LED panel: the display, a Mode Select button in the middle, and a decrease (-) and increase (+) button. This guide follows Hotronix's operator's manual from unboxing to your first cap.

Before you switch it on

  1. Take out the packaging bolt

    There is a shipping bolt (a thumb screw) on top of the press. Remove it before you turn the press on or try to close it.

  2. Give it a sturdy stand

    Hotronix calls for a stand at least 36 in long, 24 in wide and 29 in high, with a clean, clear work area around it.

  3. Plug into the right outlet

    A 120 V press needs a full 10 amp grounded circuit, and a 220 V press also needs a full 10 amp grounded circuit. Don't use a circuit that is smaller than that or already feeding another heat press or other high-draw equipment. If you need an extension cord, keep it short, heavy duty and no lighter than 12 gauge.

  4. Switch on

    The power switch is on the side of the press. Turn it on and let the press heat.

Hotronix warns that a weak or shared circuit causes erratic controls, wrong readings, slow heat-up and a tripped breaker on the press.

Set temperature and time

  1. Temperature

    Press Mode Select once. The SET and TEMP lights come on. Use + or - to set the temperature anywhere from 176°F (79°C) to 430°F (220°C). The display shows the change as you make it.

  2. Time #1

    Press Mode Select a second time. The SET and TIME lights come on. Set the first time with + or -.

  3. Time #2

    Press Mode Select a third time. All three red lights come on. Set the second time. For a single-hit job, make it the same as Time #1.

  4. Back to print mode

    Press Mode Select a fourth time. All lights go off and the press is ready to print.

Set and read the pressure

The pressure knob sits under the center of the heat platen, so pressure spreads from the middle out to the edges. Turn it clockwise to increase pressure and counterclockwise to decrease it. With the handle locked in the print position, a number from 0 to 9 shows at the lower right of the display.

Readout Pressure
0 No pressure
1 to 3 Light
4 to 7 Medium
8 to 9 Heavy

Set the pressure with a cap on the platen, because the cap's thickness changes the reading.

Hotronix's limited warranty does not cover structural damage caused by too much pressure. Raise it a little at a time.

Press a cap

  1. Wait for temperature

    Let the press reach the temperature you set.

  2. Load and lock the cap

    Position the cap and the design, then lower the cap hold-down lever under the lower platen to lock the cap in place. It stops the hat shifting during the press.

  3. Close the press

    Pull the lift handle down. The timer starts on its own.

  4. Let it open

    When the time ends, the press releases and the gas shocks lift the heat platen. Keep your hands clear of the platen as it closes and opens.

Sleep mode

If the press sits unused for two hours, it drops into an energy saving sleep mode. Press any button on the panel to wake it, then wait for it to return to the set temperature before you press.

Optional cap platens fit low-profile, low-crown, full-crown and oversized hats. If the press still won't heat or won't hold down, see our cap press troubleshooting guide or text us a short video at (562) 609-4996.

Watch Hotronix's video: Cap Heat Press unboxing and set up

Embedded from the manufacturer's official channel.

Common questions

Which way do I turn the knob for more pressure?

Clockwise increases pressure and counterclockwise decreases it. Check the readout with the handle locked in the print position.

What pressure number should I use?

Hotronix groups the 0 to 9 readout as 1 to 3 light, 4 to 7 medium and 8 to 9 heavy. Follow your transfer's instructions and remember the cap itself adds thickness.

Why are there two timers?

Time #1 and Time #2 let you set different times for a two-hit application. For a single hit, Hotronix says to set both to the same time.

The display went dim and it isn't hot. Is it broken?

Probably not. After two hours without use the press goes into sleep mode. Press any button on the panel and let it come back up to temperature.

How does it open by itself?

An electromagnet holds the handle down while the timer counts. When the time is up, gas shocks lift the heat platen into the up position.

Sources
Did this fix it?