Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Maxima or Proxima dual press: platen won't lower, timer won't start, or press won't cycle
If a Maxima or Proxima won't lower the heat plate, first confirm air: the compressor must be running, connected and delivering 85 to 100 psi, with about 60 psi on the press gauge. Next check the mode, since manual mode needs you to start each press. If the timer won't count down, the head isn't being detected in position; the Maxima manual says the proximity switch must be less than 5 mm from its target.
Match your symptom
| What you see | Most likely cause | Go to |
|---|---|---|
| Heats but the plate won't come down in any mode | No air or low air pressure | Step 1 |
| Comes down in auto but not manual (or the reverse) | Operating mode | Step 2 |
| Presses, but no countdown | Head not detected in position | Step 3 |
| When the time is up, the press does not press | Intermediate relay circuit | Step 4 |
| Doesn't heat or hold temperature | Temperature control circuit | Step 5 |
These presses move on their own in auto mode. Keep hands clear of both stations, and use the emergency stop button if anything goes wrong.
Step by step
-
Confirm air supply
The compressor should be on and delivering 85 to 100 psi. Connect it to the press, open the air, and set the press gauge to about 60 psi. If the gauge reads zero, the hose isn't connected or the air isn't open; see our air compressor guide for the right fittings. If the gauge reads low, raise it with the regulator (lift the upper valve and turn toward +). On a Proxima, also push the drain valve at the bottom of the air filter to clear water.
-
Check the operating mode
Use the Auto/Manual switch to change modes. In manual mode the Maxima presses when you press the start switch, and the Proxima when you press both Press Buttons together. In auto mode the Maxima presses on its own whenever the head is over a platen, and the Proxima Semi-Auto presses when the head reaches the left or right end. Test in manual mode first.
-
No countdown: check the head position and proximity switch
The Maxima manual gives two checks. First, make sure the machine head is fully in place over the platen. Second, check the proximity switch and its distance from its target: it must be less than 5 mm. With the power off and air disconnected, look at the gap and adjust the switch closer if needed.
-
Time is up but the press does not press
For this fault the Maxima manual points to the intermediate relay circuit. This is a parts and wiring repair. Text us a photo or short video at (562) 609-4996.
-
Not heating or not holding temperature
The manual's checks are the temperature controller, the solid state relay and the heating plate wiring. That's technician work inside the electrical box, so contact us rather than opening it.
First startup checklist (Maxima)
- Compressor connected, air open, press gauge at about 60 psi, heat plate raised
- Main power on, indicator light on
- Time and temperature set, press heated (the OUT1 light goes off when it reaches temperature)
- Garment flat on the platen with pressing paper on top, mode set to manual, start switch pressed
- Check the result, adjust, then switch to automatic
Watch DTF Station's video: How to use the Maxima Semi Auto heat press
Embedded from the manufacturer's official channel.
Common questions
The press heats but nothing moves.
That's almost always air. Check the compressor is on and full, the hose is connected at both ends, the air is turned on to the press, and the gauge reads about 60 psi.
How do I start a press in manual mode?
On the Proxima, press both Press Buttons at the same time. On the Maxima, set the mode to manual and press the start switch.
The time is up but the press doesn't press. What now?
The Maxima manual lists this fault (when the time is up, the press does not press) and points to the intermediate relay circuit. That's a parts repair, so contact us. On the Proxima Auto, remember the foot pedal is what moves the head to the other station.
Is it safe to adjust the proximity switch myself?
Turn the press off and disconnect the air first so nothing can move. If you're not comfortable with it, text us a photo of the switch and we'll guide you.