Support
Machine type
Brand
Epson SureColor G6070 DTF printer

Miro 36 (Gen 2) maintenance: daily filter rotation, weekly glycerin trays and monthly fan and filter service

✓ Reviewed by Jason KimUpdated 3 min readFits: Miro 36 (Gen 2)
Short answer

Every day, cool the Miro 36 with only the purifier running for at least 5 minutes, wipe the chamber with 90% or stronger isopropyl alcohol, swap the HEPA and charcoal filters for the dry spare set (charcoal side up), clean the powder station and sensor, and empty the powder. Clean both glycerin catch trays weekly. Monthly, clean the purifier fans and replace the HEPA, charcoal and side air filters.

The Miro 36 has two filter systems to look after: HEPA and charcoal filters in the purifier, plus side air filters. Glycerin, the oily residue from curing ink, collects in catch trays and on the purifier fans. Have gloves, isopropyl alcohol (90% or stronger, not rubbing alcohol), lint-free cloths and a brush ready. Keep the spare purifier filter set that came with the machine.

When What to do
Every day Cool down with the purifier, clean the chamber, swap in the dry spare filters, clean the powder station and sensor, empty the powder tray
Every week Remove and clean the glycerin catch trays on both sides
Monthly, or as needed Clean the purifier fans, fit new HEPA and charcoal filters, clean the lid fabric, replace the side air filters

End of every day

  1. Cool down

    Turn everything off except the purifier fan. Open the powder station cover and the main heating chamber and let the purifier run at least 5 minutes, until the main plate is at room temperature. Then turn off the purifier, push the control panel in and turn off main power.

  2. Clean the heating chamber

    Brush any powder off the main heating plate, then wipe the plate and the surfaces around it with isopropyl alcohol on a lint-free cloth. Clean the underside of the upper cover too. Close and lock the chamber.

  3. Rotate the filters

    Open the filter cover, wipe it, and wipe the fan area including the underside of the cover. Take out the HEPA and charcoal filters and set them somewhere cool and ventilated to dry. Wipe the filter housing and fit the dry spare set, charcoal side up. Close the covers.

  4. Clean the powder station

    Open the powder station and lift out the media wheel rod; brush and wipe it. Brush the powder toward the tray. Clean around the sensor without touching it with the brush, then wipe the sensor face gently with alcohol on a cloth.

  5. Empty the powder

    Pull the powder tray at the bottom and pour the powder into a sealed container. Sweep up the powder that collects under the tray. Put the tray back, lower the front heating plate, refit the media wheel rod, close the station and put the fabric cover on.

Rotating filters daily makes them last longer, but they still need replacing every month.

Every week: glycerin catch trays

  1. Remove the trays

    There is a catch tray on each side. Loosen the screws holding each one and take both out.

  2. Clean and dry

    Wipe all the glycerin off with isopropyl alcohol and a lint-free cloth. Let the trays dry completely.

  3. Refit

    Put both trays back, tighten the screws, close all covers, unplug the machine and cover it.

Monthly or as needed: fans and filters

  1. Open the purifier chamber

    Turn off main power and open the purifier chamber lid.

  2. Clean the fans

    Unscrew the fan brackets and lift out each fan. Wipe the glycerin off with alcohol, then refit each fan with its label facing up and screw the brackets back on. Switch the purifier on briefly to confirm the fans run, then off again.

  3. New HEPA and charcoal filters

    Lift off the fan cover plate, remove the old filters and fit new ones with the white side down and the gray side up. Refit the plate.

  4. Clean the lid fabric

    Take the white cotton fabric off the purifier lid, clean the grease off the back of the lid with alcohol, let it dry and refit the fabric.

  5. Replace the side air filters

    Remove the side air filters on both sides and fit new ones with the white side facing out and the gray side facing in.

  6. Close up

    Close and latch the purifier lid, unplug the machine and cover it.

Powder storage

Protect powder from air, moisture and dust. It keeps about a year. Don't leave it in the tray after use. Store used powder apart from new and mix it back in gradually.

Smoke that won't clear after new filters, or melted powder dots on the film? Text us a photo or short video at (562) 609-4996.

Watch DTF Station's end-of-day maintenance on the Miro 36 Gen 2

More videos

Miro 36 weekly maintenance: cleaning the glycerin catch tray
Miro 36 as-needed maintenance

Embedded from the manufacturer's official channel.

Common questions

Can I use rubbing alcohol on the Miro 36?

No. DTF Station specifies isopropyl alcohol of 90% or higher on a lint-free cloth.

Why rotate the filters every day?

Letting a set dry out while the spare works extends filter life. They still need replacing monthly.

Which way do the filters go in?

Daily rotation: charcoal side up. When fitting new HEPA and charcoal filters: white side down, gray side up. Side air filters: white side out, gray side in.

Where are the glycerin catch trays?

One on each side of the machine, held by screws. Clean both every week.

How long does DTF powder last?

About a year if it's sealed away from air, moisture and dust. Don't leave it sitting in the tray.

Sources
Did this fix it?