Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Prestige R1 poor nozzle check: capping station, waste-line pull and damper checks
Most R1 nozzle problems come from the capping station, not the print head. Check that the cap is centered and seals against the head and that the wiper touches it, then do a syringe pull through the waste ink tube. If only one color is missing, test that color's damper. Keep Pilot's during-print Auto Clean off and use the confidence strip. Don't print production work below 90%.
Match your nozzle check
| What you see | Most likely cause | Go to |
|---|---|---|
| Gaps in several colors, ink bubbling at the cap during cleaning | Cap off-center or not sealing | Step 2 |
| Heavy gaps everywhere after the morning routine | Clog, or the pump isn't pulling | Step 3 |
| One color missing, the rest fine | That color's damper, or a neighboring one | Step 4 |
| Black missing on the far right or white on the far left | Capping station misaligned | Step 2 |
| Good in the morning, drops after a few prints | Head strike residue, airflow, or Pilot cleaning settings | Step 5 |
| White prints dark after an ink fill | White circulation left too high | Turn the knob to 20% or below |
Step by step
-
Do the full morning routine once
Short Fill Ink, two head cleanings back to back, then a nozzle check. If it reaches 90%, you're done. If not, keep going.
-
Check the cap and wiper
Open the front capping station drawer and press Enter to raise and lower the cap. The cap should sit centered under the head face. During a cleaning, its inner layer should press firmly against the head without lifting the carriage. After the cleaning, the wiper should rise and touch the head without bending hard. Clean the cap and wiper with DTF cleaning solution. If the cap is off-center or the wiper misses, record a short video of a cleaning and send it to us.
-
Pull through the waste ink tube
Press Enter so the head seals tightly on the cap. Take the waste ink tube out of the waste bottle and attach a syringe. Pull firmly and hold: the first pull is mostly air. Disconnect, empty the syringe into the waste bottle, reconnect and pull again. This time it should fill mostly with ink. Put the tube back in the bottle, run two head cleanings, confirm ink drains through the tube, and print a nozzle check.
Only do this after the morning routine fails. Never push ink back into the tube. If you get firm resistance but no ink, there's a blockage in the tube or pump: stop and contact us.
-
One color missing? Test the damper
Hold the damper by its outer frame, never the soft center. Place the syringe over the damper opening (don't push the tip inside), and pull slowly. A good damper gives airtight resistance and smooth ink flow, and its center draws in. Foamy ink, lots of air, or no resistance means replace it, and always test a new damper before fitting it. Dampers on one head affect each other, so a missing cyan can come from the damper next to it. After replacing, Fill Ink for at least 10 seconds, run two cleanings and check again.
-
Check Pilot settings and the room
In Pilot, set the during-print Auto Clean to off and Pre-Flashing to open. Turn on the confidence strip so every color fires on every print. Make sure no fan or AC vent blows on the printer, and keep the room around 70 to 75°F and 35 to 45% humidity.
When to contact us
- No nozzle pattern prints at all.
- Firm resistance on the pull but no ink comes through.
- Both white dampers fail the test at the same time.
- The cap is visibly off-center or the wiper doesn't reach the head.
Text us a photo or short video at (562) 609-4996, including a nozzle check photo and a video of a head cleaning with a light on the cap and head.
Watch DTF Station's video: troubleshooting poor nozzle checks at the capping station
Embedded from the manufacturer's official channel.
Common questions
Is it normal to pull air on the first syringe pull?
Yes. Around 10 mL of air from the cap and tube is normal. The second pull should come back mostly ink. If you never feel firm resistance, the system has an air leak: check the dampers, the cap seal and the cap tube.
Can I push ink back into the tube from the syringe?
Never. Disconnect the syringe, empty it into the waste bottle, and reconnect.
Should Auto Clean be on in Pilot?
Not on the R1. Set the during-print Auto Clean to off: cleaning cycles mid-print can hurt the nozzles on this head. Keep Pre-Flashing on, and turn on the confidence strip so every color fires on every print.
My nozzle check is fine in the morning but drops after a few prints. Why?
Look for a recent head strike (did the head ever smear ink on the film?), a fan or AC blowing on the printer, and how close the cap sits when it flashes. Print a nozzle check before and after a job and send us both.
When do I need a new print head?
Heads typically last 1 to 2 years. If the cap, wiper, pull and dampers all check out and the pattern stays the same, send us your nozzle checks before buying one.