Support
Machine type
Brand
DTF Station Prisma Sentry Heat Press

Prisma Swing and Sentry: switching °F and °C and calibrating the temperature (Pb offset)

✓ Reviewed by Jason KimUpdated 2 min readFits: Prisma Swing · Prisma Sentry
Short answer

Both presses keep °F/°C and the temperature offset (Pb) in a second-level menu. On the Swing, hold SET for 4 seconds; on the Sentry, hold minus and plus, press SET, then enter code 68. Measure the platen with a surface probe, set Pb by the difference between the probe and the screen, hold SET 4 seconds to save, then measure again to confirm.

If your transfers fail even though the screen shows the right number, the platen may not be at the temperature the screen says. Both Prisma presses let you correct this with an offset called Pb. The same hidden menu also switches the display between Fahrenheit and Celsius.

Match your symptom

What you see What to do
Screen in °C, you want °F Change the unit setting below
Probe and screen differ Set the Pb offset below
Corners colder than center Not an offset problem. Text us your readings
Temperature drifts or jumps Check the circuit and plugs first, see the not-heating guide

Measure first

  1. Heat and wait

    Set a normal working temperature and let the press sit at it for at least 10 minutes.

  2. Probe the platen

    Touch a contact surface probe to the center of the heat platen and note the reading. Check a few spots so you know whether the heat is even.

  3. Work out the difference

    Compare the probe reading with the screen. That gap is the number you'll enter as Pb.

Prisma Swing

  1. Open the second menu

    Press and hold SET for 4 seconds.

  2. Change °F or °C

    Press SET until the screen shows SL2. Use the arrows to set 0 for Celsius or 1 for Fahrenheit.

  3. Set the offset

    Press SET until the screen shows Pb. Use the arrows to set the offset. The Swing manual says: if the platen is hotter than the screen, raise Pb. Example: platen 190, screen 185, set Pb to +5. If the platen is cooler, lower Pb.

  4. Save

    Press and hold SET for 4 seconds to leave the menu.

Prisma Sentry

  1. Unlock the menu

    Press and hold minus and plus together, then press SET. The screen shows LCK.

  2. Enter the code

    Enter 68 to open the second-level menu.

  3. Change °F or °C

    Press SET to reach the unit setting, then use the arrows: 0 for Celsius, 1 for Fahrenheit.

  4. Set the offset

    Press SET until the screen shows Pb and use the arrows to change it. The Sentry manual says: if the platen is hotter than the screen, lower Pb. Example: platen 190, screen 185, set Pb to -5. If the platen is cooler, raise Pb.

  5. Save

    Press and hold SET for 4 seconds to leave the menu.

The two manuals give the offset in opposite directions, and controllers vary. Always measure again after 10 minutes. If the gap got bigger instead of smaller, enter the same number with the opposite sign.

Check your work

After saving, let the press settle for 10 minutes and probe it again. The screen and the probe should now agree within a few degrees. If you can't get them to agree, or the reading keeps wandering, text us a photo of the screen and your probe readings at (562) 609-4996.

Common questions

How do I know if my press needs calibrating?

Heat it to a set point, wait at least 10 minutes, and measure the platen with a contact surface probe. If the probe and the screen differ by more than a few degrees, adjust Pb.

The screen and the probe agree in the middle but the corners are colder. Will Pb fix that?

No. Pb shifts the whole reading up or down. A platen that heats unevenly needs a look from us: text us your probe readings.

The Sentry shows LCK and won't let me in.

That's the lock screen. Enter 68 to open the second-level menu. If it still won't open, contact us.

What do 0 and 1 mean in the unit setting?

0 is Celsius and 1 is Fahrenheit, on both presses.

Did this fix it?