Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Prisma Swing and Sentry: switching °F and °C and calibrating the temperature (Pb offset)
Both presses keep °F/°C and the temperature offset (Pb) in a second-level menu. On the Swing, hold SET for 4 seconds; on the Sentry, hold minus and plus, press SET, then enter code 68. Measure the platen with a surface probe, set Pb by the difference between the probe and the screen, hold SET 4 seconds to save, then measure again to confirm.
If your transfers fail even though the screen shows the right number, the platen may not be at the temperature the screen says. Both Prisma presses let you correct this with an offset called Pb. The same hidden menu also switches the display between Fahrenheit and Celsius.
Match your symptom
| What you see | What to do |
|---|---|
| Screen in °C, you want °F | Change the unit setting below |
| Probe and screen differ | Set the Pb offset below |
| Corners colder than center | Not an offset problem. Text us your readings |
| Temperature drifts or jumps | Check the circuit and plugs first, see the not-heating guide |
Measure first
-
Heat and wait
Set a normal working temperature and let the press sit at it for at least 10 minutes.
-
Probe the platen
Touch a contact surface probe to the center of the heat platen and note the reading. Check a few spots so you know whether the heat is even.
-
Work out the difference
Compare the probe reading with the screen. That gap is the number you'll enter as Pb.
Prisma Swing
-
Open the second menu
Press and hold SET for 4 seconds.
-
Change °F or °C
Press SET until the screen shows SL2. Use the arrows to set 0 for Celsius or 1 for Fahrenheit.
-
Set the offset
Press SET until the screen shows Pb. Use the arrows to set the offset. The Swing manual says: if the platen is hotter than the screen, raise Pb. Example: platen 190, screen 185, set Pb to +5. If the platen is cooler, lower Pb.
-
Save
Press and hold SET for 4 seconds to leave the menu.
Prisma Sentry
-
Unlock the menu
Press and hold minus and plus together, then press SET. The screen shows LCK.
-
Enter the code
Enter 68 to open the second-level menu.
-
Change °F or °C
Press SET to reach the unit setting, then use the arrows: 0 for Celsius, 1 for Fahrenheit.
-
Set the offset
Press SET until the screen shows Pb and use the arrows to change it. The Sentry manual says: if the platen is hotter than the screen, lower Pb. Example: platen 190, screen 185, set Pb to -5. If the platen is cooler, raise Pb.
-
Save
Press and hold SET for 4 seconds to leave the menu.
The two manuals give the offset in opposite directions, and controllers vary. Always measure again after 10 minutes. If the gap got bigger instead of smaller, enter the same number with the opposite sign.
Check your work
After saving, let the press settle for 10 minutes and probe it again. The screen and the probe should now agree within a few degrees. If you can't get them to agree, or the reading keeps wandering, text us a photo of the screen and your probe readings at (562) 609-4996.
Common questions
How do I know if my press needs calibrating?
Heat it to a set point, wait at least 10 minutes, and measure the platen with a contact surface probe. If the probe and the screen differ by more than a few degrees, adjust Pb.
The screen and the probe agree in the middle but the corners are colder. Will Pb fix that?
No. Pb shifts the whole reading up or down. A platen that heats unevenly needs a look from us: text us your probe readings.
The Sentry shows LCK and won't let me in.
That's the lock screen. Enter 68 to open the second-level menu. If it still won't open, contact us.
What do 0 and 1 mean in the unit setting?
0 is Celsius and 1 is Fahrenheit, on both presses.