Vastex D-100 and D-1000 Entry Level Infrared Conveyor Dryers

Vastex D-100 and D-1000 dryer assembly: building the chamber, wiring the heater and fitting the belt

✓ Reviewed by Jason KimUpdated 3 min readFits: D-100 · D-1000
Short answer

Build the chamber panels around the heater (wires to the back), set it into the conveyor cutouts, then with the cord unplugged feed the two tan heater wires and the green ground through the bed. Push the tan wires onto the heat control terminals and bolt the ground to its stud. Thread and pin the belt, raise the aligner about 1 1/2 in, track it, and fit the chain and belt guards before first power.

The D-100 conveyor ships in one piece. The D-1000 conveyor comes in two halves. Use a 1/4 in nut driver (or socket) and a 7/16 in wrench. Vastex supplies flat plate wrenches in both sizes. Don't overtighten the sheet metal screws.

D-1000 only: join the conveyor

Slide the two halves together so the inner and outer joiner plates interlock, and fit six screws on each side.

Build the chamber

  1. Height knobs

    On each side panel, fit the knob and bolt through the pointer and spacer from the outside, into the weld nut and hex nut on the inside.

  2. Panels

    Attach the front panel, then the back panel, to the left side panel, then both to the right side panel, with three sheet metal screws at each corner.

  3. Heater

    Install the heater with its wires toward the back of the chamber, using the four heater mounting pins (two each side). Check the pins are in before you go on.

Mount the chamber and wire the heater

  1. Set it on the conveyor

    Slide the chamber's corner tabs into the cutouts in the conveyor, heater wires toward the back, and attach it with three screws each side.

  2. Feed the wires through

    With the power cord unplugged and the belt off, pass the three heater wires one at a time through the hole in the conveyor bed: the two tan wires first, then the green.

  3. Lay the conveyor on its side

    Carefully tip the dryer onto its side so you can reach the controls underneath.

  4. Connect the heater wires

    Push each tan wire's connector onto either open terminal on the heat control. It doesn't matter which goes where. They should be hard to push on; tug gently to check each one is held firmly.

  5. Connect the ground

    Remove the wing nut and lock washer from the grounding stud, put the green wire's ring terminal on, and refit the lock washer and wing nut tightly. Push any slack wire back up through the hole.

Fit the belt

  1. Thread it

    With the dryer still on its side, pass the belt over the aligner bar and both braces. Then set the dryer back on its feet.

  2. Join it

    Line up the belt edges and push the connecting pin through. You can trim the pin ends.

  3. Tension it

    Center the belt on both rollers and raise both sides of the aligner equally, about 1 1/2 in. Tension only enough to stop the belt slipping on the drive pulley.

  4. Track it

    On a flat surface, run the belt at full speed and watch both rollers. Raising one side of the aligner moves the belt the other way. Make 1/4 turn adjustments and give the belt time to respond. Never let it run off the rollers, and don't leave it unattended.

Finish up

  1. Tidy the wires

    Pull gently up on the wires to take excess out from under the bed. Secure them with the high temperature tie wrap and trim it.

  2. Covers

    Position the wires behind the wire cover and fit it with two screws. Fit the top cover with its screws.

  3. Guards

    Hook the chain guard's bottom tabs into the slots below the drive chain, pivot it up and secure it. Fit a belt guard on each side at the rear of the conveyor with two screws each. Never run the dryer with the chain guard off.

Power it

The 120 V D-100 needs a dedicated 15 A circuit with a new commercial-duty NEMA 5-15R receptacle; the 120 V D-1000 needs a dedicated 20 A circuit with a 5-20R. The 240 V versions need a good quality 6-15R. Then follow our D-100 and D-1000 start-up and cure settings guide: belt on first, then heat.

Text us a photo or short video at (562) 609-4996 if a connection or part doesn't match.

Common questions

Does it matter which tan wire goes on which terminal?

No. Vastex says either heater wire can go on either open terminal of the heat control. Just make sure each push-on connector is fully seated and tight.

The connectors are very hard to push on.

That is intended. Vastex wants a tight connection. Push firmly until fully seated, then tug gently to check.

Can I run it without the belt to test the heat?

No. Vastex says not to operate the dryer without the belt installed, and the belt must be moving whenever the heater is hot.

Can I add length to a D-1000?

Yes, Vastex sells a 10 in extension. With power disconnected, remove the chamber and belt, separate the conveyor halves, fit the extension between them, splice in the belt extension piece and reassemble.

What outlet does the D-100 need?

The 120 V model needs a dedicated 15 A circuit with a new commercial-duty NEMA 5-15R receptacle. The D-1000 needs a dedicated 20 A circuit with a 5-20R.