Short answer

If the belt drifts, raise or lower the belt aligner a quarter turn at a time: raising one side moves the belt the other way. If the belt won't move, check the 1 amp AGC fuse on the control plate (one on 120 V models, two on 240 V). Chain slack should total 0.25 to 0.38 in. No heat with a working belt points to the heat control or heater, which Vastex replaces, so contact us.

Match your symptom

What you see Likely cause Go to
Nothing works at all Dryer unplugged or a building wiring fault Step 1
Belt drifts to one side or rides up a pulley edge Aligner needs adjusting Step 2
Belt slips on the drive pulley Belt too loose Step 3
Heat works but the belt won't move Blown fuse, speed control or belt motor Step 4
Belt runs rough, jerks or skips Chain too loose or too tight Step 5
Belt runs but no heat Heat control or heater assembly Step 6

Before any adjustment: turn the heat off, keep the belt running until the heater is at 300°F (149°C) or lower, then switch off and unplug. Do belt tracking with covers on and never leave the conveyor unattended while tracking.

Step by step

  1. Check power

    Make sure the dryer is plugged in. If it is and nothing works, have the building wiring checked.

  2. Track the belt

    With the dryer on a flat surface and the belt at full speed, watch where it sits on both rollers. Raising the belt aligner on one side moves the belt toward the opposite side; lowering it moves the belt toward that side. Turn the adjuster bolts a quarter turn at a time and give the belt time to respond. Don't let it run off a roller, or the belt can be damaged.

  3. Belt tension

    Tension only enough to stop the belt slipping on the drive pulley. When fitting a belt, Vastex raises both sides of the aligner equally by about 1-1/2 in, then fine-tunes the tracking.

  4. Belt won't move

    Unplug the dryer and check the fuse on the control plate: a 1 amp AGC fast-blow, one on 120 V models and two on 240 V models. Replace a blown fuse with the same rating. If a new fuse blows again, or the fuse is fine, the speed control or belt motor may be at fault. Vastex replaces those, so contact us.

  5. Chain tension

    With the chain guard removed and the dryer unplugged, move the slack part of the drive chain up and down. Total movement should be 0.25 to 0.38 in. Too tight wears the chain fast; too loose can skip a sprocket tooth. Refit the chain guard before running.

  6. No heat

    If the belt runs but the heater stays cold, Vastex points to a faulty heat control or heater assembly. Remember the red light comes on even when the controller has failed. Text us a photo or short video at (562) 609-4996 so we can sort out the right part.

Vastex lists abnormal vibration, noise, a strong smell or smoke as reasons to shut the dryer off and have it checked. Do that, and contact us.

Common questions

Does the belt have to be perfectly centered?

No. Vastex says it doesn't have to be perfectly centered, but it must never hang over either edge of a pulley.

How tight should the belt be?

Only tight enough to stop it slipping on the drive pulley. Don't over-tension it.

The red heat light is on but there's no heat. Is the control fine?

Not necessarily. Vastex says the red light comes on whenever the control is switched on, even if the controller has failed.

What fuse does it use?

A 1 amp AGC fast-blow fuse protects the belt drive circuit. 120 V dryers have one; 240 V dryers have two.