Vastex E-200 or E-2000 exposure unit not holding vacuum: what to check in order

✓ Reviewed by Jason KimUpdated 2 min readFits: E-200 (E200-2128, E200-2331) · E-2000 (E2-2536, E2-5236)
Short answer

Work through Vastex's list in order: is the pump running, is the rubber blanket torn, are the vacuum holes in the rear screen stop clear, is the pump exhaust tube clear, is the rear glass seal intact and the glass pushed tight against it, and does the lid seal touch the glass on all four sides. Most leaks come from a cut blanket, a blocked stop or glass that has slipped off its rear seal.

The vacuum pump pulls air out between the rubber blanket and the glass. Any gap, cut or blocked passage stops the blanket from pulling flat, and the stencil comes out soft. Check these in Vastex's order. Unplug the unit before you remove the glass.

Match your symptom

What you see Check first
Pump silent Step 1
Pump runs, blanket stays loose Steps 2 to 4
Pulls down then lets go Steps 5 and 6
Edges never seal Step 7

Step by step

  1. Pump running?

    Start a cycle and listen. If it doesn't run, check the lid is locked (the lid limit switch stops the cycle when it's open), then contact us.

  2. Blanket damage

    Look over the rubber blanket for holes or cuts, especially where frame corners sit. Keep screens inside the marked area and free of sharp edges.

  3. Screen stop holes

    The vacuum is drawn through holes in a rear screen stop: the left stop on the E-200, the right stop on the E-2000, and all nozzles on the E2-5236. Make sure they're not blocked, then turn the pump on and feel for suction.

  4. Pump exhaust tube

    On the E-200 a clear tube sticks out of the left side of the cabinet; on the E-2000 it's attached to the pump under the light box. It must be unobstructed.

  5. E2-5236 manifold tubes

    On the 52 x 36 unit, check the four tubes between the vacuum manifold and the nozzles are connected and not pinched.

  6. Rear glass seal

    The glass must sit tight against the seal at the back. Try tightening the three front cams slightly. If that doesn't help, unplug, pull the glass forward, inspect the seal, then reseat the glass squarely against it and retighten the cams (see our glass cleaning guide).

  7. Lid seal

    A foam seal runs around the lid between the blanket and the frame. With the lid locked, check that the seal and blanket touch the glass on all four sides. If they don't, the lid needs lowering. Vastex's manual covers this, but it involves removing the lift cylinders and moving the lid in steps of no more than 1/16 in, so contact us and we'll walk you through it.

Keep the lid raised when the unit isn't in use. Vastex says it extends the life of the lift cylinders and the rubber blanket.

Still losing vacuum after all seven checks? Text a short video of a cycle to (562) 609-4996.

Common questions

How do I know the pump is working?

Turn it on and feel for suction at the screen stop nozzle (the left stop on the E-200, the right stop on the E-2000; all nozzles on the E2-5236).

Can a sharp screen frame damage the blanket?

Yes. Vastex says every surface that touches the blanket must be rounded and smooth, and screens must stay inside the marked area.

How tight should the glass cams be?

Just enough to press the glass against the rear seal. If it still leaks, tighten them a little more. Don't overtighten.

The lid seal doesn't touch the glass. Can I adjust it?

Vastex's manual shows how to lower the lid at the rear and front, in steps of no more than 1/16 in. Contact us before you try it and we'll walk you through it.

Did this fix it?