Vastex E-20, E-200 and E-2000 LED Screen Exposing Units

Vastex exposure unit setup: lid cylinders, vacuum time, exposure time and E-2000 presets

✓ Reviewed by Jason KimUpdated 3 min readFits: E-20 · E-200 · E-2000
Short answer

On the E-200 and E-2000, fit the two lid lifting cylinders before first use. Load the screen against the rear stops, lay the string over the frame, lock the lid, then set vacuum time so the blanket is flat before the lights start, and exposure time for your emulsion. Vastex's rough starting points with LEDs are 10 to 30 seconds for pure photopolymer and 1 to 5 minutes for dual cure, but the only reliable way to set it is an exposure calculator test.

First setup

  1. Unpack carefully

    Keep the lid locked closed while you lift the unit out of the crate, and don't damage the rubber blanket. Set it on a flat surface; an uneven surface can crack the glass.

  2. E-2000 legs

    Place the legs 28.5 in (72.5 cm) apart, lock the lid handles and, with two people, lower the unit onto them. Bolt with eight 3/8 in bolts and serrated nuts.

  3. Lid lifting cylinders (E-200, E-2000)

    The cylinders ship loose and strapped to the cabinet. Remove the acorn nut from the upper stud on each side of the lid, unlock and lift the lid just enough to slide each cylinder on, and refit the nuts. Snug them with a 5/8 in wrench only; don't overtighten.

  4. E-20 glass

    The E-20's glass is sold separately (or use 1/4 x 21 x 25 in clear float glass with polished edges; tempered is best). Slide it between the retainers and seat it against the back retainer.

Exposing a screen

  1. Clean the glass

    Wipe it with a lint free rag.

  2. Load the screen

    Place the screen with the positive attached on the glass. On vacuum units push it against the two rear screen stops and keep it inside the marked area. On the E-20, lay the pressure plate on top, with up to about 10 lb of extra weight if you like.

  3. String and lid

    On the E-200 and E-2000, lay the small string at the back over the screen frame, lower the lid and lock both handles.

  4. Set times and start

    See the controls below. The pump runs for the vacuum time, then the LEDs come on for the exposure time, then both shut off.

  5. Release

    Unlock the lid to break the vacuum and take out the screen.

Controls by model

Model How to set and start
E-20 Rocker switch to the middle for power. Set the dial (factory scale 0 to 5 minutes, mode B). Push the switch up to start. Switch off at end of shift.
E-200 Power on. Vacuum timer is factory set to a 0 to 1 minute scale, mode B. Set the exposure timer (0 to 999) with its four buttons; S means seconds, M minutes. Press start.
E-2000 Power on, then use the touchscreen (below).

On the analog timers, you can change the time scale with the RANGE SELECT screw: right increases it, left decreases it. Leave the mode set to B.

E-2000 touchscreen

  1. Enter a time

    On the home screen choose ENTER TIME (it defaults to 10 seconds vacuum and 10 seconds exposure). Tap the number under VACUUM, enter 0 to 999 seconds, press ENTER. Do the same under EXPOSURE.

  2. Run

    Press RUN. The run screen counts down. CANCEL stops the cycle. Press OK at EXPOSURE COMPLETE.

  3. Save a preset

    On the setup screen choose SAVE PRESET and pick a letter. Check what's already stored there before overwriting. It holds up to 10 presets.

  4. Load a preset

    From home choose SELECT PRESET, pick it and press LOAD.

Message What to do
WAITING FOR CLOSED LID CANCEL, lock the lid down, RUN again
LID WAS OPENED Keep the lid shut for the full cycle. If it opened during exposure, start again with a fresh screen.
POWER FAILURE Power was lost mid cycle. If during exposure, redo with a fresh screen.

Finding your exposure time

Vastex ranks the variables in this order: emulsion type and brand, stencil thickness (coats or capillary film), mesh color and humidity. Run an exposure calculator test whenever you change any of them. Start from 10 to 30 seconds for pure photopolymer and 1 to 5 minutes for dual cure with these LEDs. Washing out soft or losing fine detail? Text us a photo of the test at (562) 609-4996.

Common questions

How long should I expose?

It depends mostly on the emulsion type and brand, then stencil thickness, mesh color and humidity. Vastex says to determine it with an exposure calculator. Rough LED starting points: 10 to 30 seconds for pure photopolymer, 1 to 5 minutes for dual cure.

How long should the vacuum run?

Time how long the blanket takes to pull flat past the edge of your positive. On the E-200 that's typically just under a minute. If unsure, wait until it's flat to within 2 in of the frame.

What is the little string for?

Lay it over the edge of the screen frame. It helps the vacuum reach the center of the screen.

The E-2000 says WAITING FOR CLOSED LID.

Press CANCEL, lower and lock the lid, then press RUN again.

Can I use a bigger screen than the labels show?

No. Screens outside the marked area can damage the vacuum blanket. Screens must also be free of sharp edges.

Did this fix it?