Arc 127 maintenance: end-of-day blade cleaning and air release, and weekly water draining

✓ Reviewed by Jason KimUpdated 2 min readFits: Arc 127
Short answer

At the end of each day, power the cutter off, shut off and unplug the compressor, close its valve and pull the air tube so the trapped air escapes. Then clean the blade and holder with alcohol, vacuum the cutting bed, empty the catch basket and cover the machine. Once a week, drain the water from the filter bowl inside the cutter and from the compressor's tank.

The Arc 127 needs very little daily care, but the two jobs it does need matter. Scraps and adhesive on the blade spoil cut quality. Water from the compressed air collects in the lines, and the user manual warns that leaving it there makes the air cylinders work harder and can damage the pneumatic parts.

End of day

  1. Power off the cutter

    Turn off the main power switch and unplug the main power cord.

  2. Shut off the compressor

    Press the compressor's power switch down to turn it off, close the air outlet valve on the compressor, and unplug it.

  3. Release the air

    Pull the connector's lock backward and take the air tube out. That lets the air trapped inside the cutter escape so water can't sit in the system overnight.

  4. Clean the blade and holder

    Put on gloves. Loosen the screw that holds the blade holder and remove it. Pick off any film scraps around the blade and holder, then wipe both with isopropyl alcohol on a lint-free wipe. Refit the holder before you start the next day, checking that only the tip of the blade shows.

  5. Clear the bed and basket

    Vacuum the cutting platform to pick up small scraps, and empty the waste film from the catch basket.

  6. Cover the cutter

    Put the dust cover on so dust and debris stay off the belt and camera overnight.

Never reach near the blade or the carriage while the cutter is powered. Always switch off and unplug first.

Once a week

  1. Drain the filter bowl in the cutter

    Go to the take-up reel side of the machine and remove the cover. The oil and water filter is on the right, with a clear bowl underneath. If you can see water in the bowl, hold a paper towel under it and pull the drain ring down until the water is gone.

  2. Drain the compressor tank

    Find the drain plug on the compressor's air tank, underneath the machine. Unscrew it and let all the water run out, then screw it back in snugly.

Match your symptom

What you see Likely cause What to do
Ragged edges, pieces won't pop out Dirty or worn blade Clean it, run a blade test, then replace it
Water in the filter bowl every week Normal condensation Keep draining weekly
Clamp slow or weak Water in the air system, or low air pressure Drain the bowl and tank, check the gauge passes 60 psi
Film slides during cutting Scraps on the bed, vacuum not on Vacuum the bed, turn the vacuum on before cutting

Cut quality problems that cleaning doesn't fix are covered in our Arc 127 cut problems guide. If the clamp stays weak after draining, or you find oil or a lot of water every day, text us a photo or short video at (562) 609-4996.

Watch DTF Station's video: Arc 127 daily maintenance

More videos

Arc 127: weekly maintenance

Embedded from the manufacturer's official channel.

Common questions

Why do I have to release the air every night?

Compressed air carries moisture. Releasing it at the end of the day keeps water from building up inside the machine, where it can damage the air parts.

The manual says drain the filter monthly, but DTF Station says weekly. Which is right?

Follow DTF Station's weekly routine. The manual's once a month is the bare minimum, and draining more often does no harm.

What should I clean the blade with?

Alcohol. We use isopropyl alcohol on a lint-free wipe. Wear gloves, because the blade is very sharp.

When should I replace the blade?

When cuts come out rough or don't go all the way through, even after you clean the blade and rerun the blade test.