Support
Machine type
Brand
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses

Geo Knight DK20S and DK20SP setup: bench and cord, temperature and time, 70 presets, prepress timer and user menus

✓ Reviewed by Jason KimUpdated 4 min readFits: Geo Knight DK20S · DK20SP (Digital Knight controller)
Short answer

Put the press on a firm bench 27 to 32 inches high and strap the power cord to the back post so swinging the head never tugs the inlet. Press TEMP to set temperature and use the arrow keys alone to set time. Press PRG, pick a preset from 00 to 70 and press PRG again to load it; to edit one, press TEMP while SET is showing. Press TEMP and PRG together to open the user menus, where you turn on the prepress timer (PPR), alarms and °F or °C.

Set up the press

  1. Choose a firm bench

    Geo Knight suggests a work surface 27 to 32 inches high. The higher the press, the harder it is to close and lock the DK20S. Bolting it down through the rear holes in the base is recommended but not required. Geo Knight also sells a stand on lockable casters.

  2. Plug the cord in under the head

    The modular power cord plugs into the inlet under the top head.

  3. Strap the cord

    Geo Knight highly recommends tying the cord to the back white post. Then swing the head both ways and check the cord moves freely, doesn't pull on the inlet and can't be touched by the heater.

  4. DK20SP only: connect air

    The air inlet is a 1/4 or 3/8 inch female NPT thread. A standard male NPT fitting and 1/4 or 3/8 inch ID hose give enough air. See compressor setup.

  5. Leave it open between jobs

    Keep the heat platen up and swung over the table when you aren't pressing. Don't leave the hot platen resting on the silicone pad.

Temperature and time

  • Temperature: press TEMP. The flashing number is the setting, not the actual temperature. Use the arrow keys (hold to change quickly, or press both together for 350°F), then press TEMP again to lock it in.
  • Time: from the normal screen, use the arrow keys only. Don't touch PRG. Hold an arrow more than 2 seconds to change quickly; press both to reset to 00.
  • READY shows when the actual temperature is within 5 degrees of the setting. The screen also shows OPEN, TIMING or DONE.

Pressure

DK20S: clockwise on the black knob increases pressure; counterclockwise decreases it. The press must lock in place with a firm two-handed close and a solid click. The bar graph reads 0 to 3 for light, 4 to 6 for a good medium, and 7 to 9 for very heavy pressure on demanding items, and it only updates once the press is closed and timing. DK20SP: pressure comes from the air regulator and gauge, not the knob. The knob only sets the platen height for thick items; Geo Knight wants a 1/2 to 3/4 inch gap between the heater and the pad or workpiece. Start the DK20SP by pressing both black buttons together; the red E-Stop button must be up for the press to run.

The prepress timer

The prepress timer runs a short press before the main one, for example 5 seconds then 20. Turn it on in the user menus (PPR to ON). When PREPRESS shows next to the time, the arrows set the prepress time. If it isn't showing, quickly close and open the press to switch to it. The press counts the prepress time when you close it, then switches to the main time when you open it.

Load and save presets

  1. Load a preset

    Press PRG. SET appears. Pick a preset from 00 to 70 with the arrows and press PRG. The temperature, time and prepress time update, and the screen briefly shows the pressure to set (for example PRS 6).

  2. Edit a preset

    Press PRG, pick the number, then press TEMP to step through temperature, time, prepress time and pressure reference, setting each with the arrows. Set prepress to 00 if that job uses one timer.

  3. Finish

    After the pressure reference, press TEMP to go back to the preset number, then PRG to return to normal. On the DK20SP you can skip the pressure reference or use it as a reminder of your psi.

User menus

Press TEMP and PRG at the same time. Use the arrows to change a value and PRG to move on.

Menu What it does
F / C Fahrenheit or Celsius
CNT Timer in minutes and seconds (default) or hours and minutes
REC Pressing counter; arrows reset it to 0
CTD Countdown counter that replaces the timer display
DRP Alarm if temperature drops 10, 20, 30 or more degrees below the setting
DTD Timer won't run while temperature is that far below the setting
BEP Keypad beep on or off
ALR Timer alarm pattern, off or 1 to 10
FWB Beep in the last 3 seconds of a cycle
PPR Prepress timer on or off
AL2 Prepress alarm pattern (shows when PPR is on)

The Pressure Minimum and Pressure Maximum menus recalibrate the bar graph. Geo Knight says not to adjust them unless you're sure it's needed. Operator lockout is set up through Geo Knight, not the menus.

For general pressing, Geo Knight suggests a 2 to 4 second prepress to take out wrinkles and moisture, and keeping collars, cuffs and zippers off the lower table. Follow your transfer maker's settings over any generic chart.

If the timer won't start when you close the press, the keys stop responding, or the screen shows Err, see heat press won't turn on or heat or Text us a photo or short video at (562) 609-4996.

Watch Geo Knight: Digital Knight control and instructions

More videos

Geo Knight: the Digital Knight heat press control system

Embedded from the manufacturer's official channel.

Common questions

Does a preset set the pressure for me?

No. The preset only shows a pressure reminder (for example PRS 6) when you load it. You still set pressure with the knob on the DK20S, or the air regulator on the DK20SP.

How do I get to 350°F quickly?

Press TEMP, then press both arrow keys together. The setting jumps to 350°F. Press TEMP again to lock it in.

How do I reset the timer to zero?

In the normal operating mode, press both arrow keys together.

The user menus won't open, I get the temperature setting instead.

Press TEMP and PRG at exactly the same moment, ideally with two hands. If one key lands first, turn the press off and on and try again.

Should I change Pressure Minimum or Pressure Maximum?

No, not unless you are sure it's needed. Those menus redefine 0 and 9 on the pressure bar graph. Contact us first.

Did this fix it?