Support
Machine type
Brand
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses

Insta 718, 728 and 828 controller: temperature, timer, five presets, counter, sleep mode and temperature offset

✓ Reviewed by Jason KimUpdated 2 min readFits: Insta 718 · 728 · 828
Short answer

Press POWER/MODE (or MODE) to choose the temperature, timer or counter display, then hold SET and press the arrows to change it. To program the five presets, hold POWER/MODE and PGM for 3 to 5 seconds until a preset light blinks. Sleep time, set back temperature, auto shut off, °F/°C and the user offset live in a menu you open by holding SET then POWER/MODE for 3 to 5 seconds with the counter showing.

The 718, 728 and 828 share one digital controller. It has four buttons you'll use: POWER/MODE (labeled MODE on some panels), SET, the up and down arrows, and PGM. A row of five lights above PGM shows which preset is active.

Everyday settings

  1. Change the temperature

    Press POWER/MODE until the temperature shows. Hold SET and press up or down to reach your setting. The range is 125 to 450°F.

  2. Change the timer

    Press POWER/MODE until the timer shows, then hold SET and use the arrows. The timer reads minutes:seconds from 00:00 to 10:00, and the colon flashes while it counts. When it reaches zero the press opens automatically.

  3. Pick a preset

    Press PGM until the light for the preset you want is on. For a one-off setting, keep pressing PGM until no light is lit; that sixth slot is your manual setting.

Program the five presets

  1. Enter programming

    Hold POWER/MODE and PGM together for 3 to 5 seconds until a preset light starts blinking.

  2. Choose the preset

    Press PGM to move the blinking light to preset 1, 2, 3, 4 or 5.

  3. Set its temperature and time

    Use POWER/MODE to show temperature, then hold SET with the arrows. Repeat for the timer.

  4. Repeat and exit

    Do the same for the other presets, then hold POWER/MODE and PGM for 3 to 5 seconds until you hear one beep.

Outside programming mode, no preset light blinks and presets can't be changed by accident.

Cycle counter

Press POWER/MODE until the counter shows (0000 to 9999). To zero it, hold the up and down arrows together for 3 seconds.

Sleep, set back, auto shut off, °F/°C and offset

These five settings sit in one menu. Show the counter, then hold SET and then POWER/MODE together for 3 to 5 seconds. Inside the menu, press POWER/MODE to step to the next item and hold SET with an arrow to change it.

Display Setting Range
1._XX Sleep time OFF to 99 minutes
2._XXX Set back temperature 225 to 300°F
3._XX Auto shut off time OFF to 99 minutes
4._X Temperature unit F or C
5._XX User offset Offset number

To leave the menu, hold SET then POWER/MODE for 3 to 5 seconds.

  • Sleep drops the platen to the set back temperature after the idle time you choose. Any key press or press cycle wakes it and restarts the timers.
  • Auto shut off turns heat off after its idle time. If sleep is OFF, the shut off timer still runs and restarts after every key press or cycle.

Using the offset

If your transfers behave as if the press runs hot or cold, check the platen with a surface probe pyrometer at your working temperature. If the reading and the display don't agree, enter the menu, step to 5._XX, and adjust the offset until the display matches what you measured. Check again after the platen settles. If the difference is large or keeps changing, the temperature sensor may be failing. Text us at (562) 609-4996.

The controller also has a factory tier behind a code that controls the safety delay on the start buttons. Leave it alone. The delay protects your hands.

Common questions

What temperature and time range does the controller allow?

125 to 450°F (52 to 232°C) and 1 second to 10 minutes.

Are my settings saved when I turn the press off?

Yes. Both the five presets and the manual setting (no preset light lit) are kept when the power is off.

How do I reset the press counter?

Show the counter, then hold the up and down arrows together for 3 seconds until it reads 0000.

My press displays a different temperature than my thermometer. Can I fix it?

Yes, with the user offset (menu 5). Measure the platen with a surface probe first, then shift the display to match.

Why did my press cool down on its own?

Sleep mode drops it to the set back temperature after a period with no button presses or cycles. Any key press or press cycle wakes it.