Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Insta 907 setup and operation: power, air, two-station shuttle pressing and the five presets
Put the 907 on its own 15 A circuit, connect 30 to 100 psi of air, turn it on and set temperature and time. Swing the heated arm directly over one lower platen and hold both start buttons until the platens touch; the press then times and opens itself. Load the second station while the first presses. Presets are programmed by holding PGM then MODE for 3 to 5 seconds.
The 907 works like a small automatic press with two lower stations. The heated upper arm swings from one station to the other, and air closes the press. These steps follow Insta's 907 manual.
Before you plug in
- Circuit: a separate 15 A circuit at 120 V. International 230 V units need a designated 16 A circuit.
- Surface: secure and flat, with the base of the press above the wall socket.
- Extension cords: industrial only, 18/3 up to 25 ft or 16/3 up to 50 ft.
- Air: a compressor or shop line that can hold 30 to 100 psi. US machines ship with a standard air fitting.
Don't repair or replace a damaged power cord yourself. Insta says it must come from the manufacturer. Contact us.
Run a cycle
-
Power on
Push the ON/OFF switch to ON.
-
Set temperature
Press MODE until temperature shows. Hold SET and press up or down. The range is 125 to 450°F.
-
Let it heat
Wait until the platen reaches the set temperature.
-
Set pressure
Turn the air regulator until the gauge shows the pressure you want, between 30 and 100 psi.
-
Set time
Press MODE until the timer shows, then hold SET and use the arrows. The range is 1 second to 10 minutes.
-
Load station one
Smooth the garment on the lower platen and place the label or transfer.
-
Swing the arm over it
Bring the heated arm directly over that lower platen. The press won't run unless the arm is lined up over one of the two platens.
-
Hold both start buttons
Hold both buttons together until the lower platen meets the heated platen. From there it's automatic: it seals for the set time and releases.
-
Load station two meanwhile
While station one presses, prepare the next garment on the other platen. When the first opens, swing the arm across and repeat.
Press DISENGAGE at any time to stop a cycle. The timer resets.
Presets and counter
- Pick a preset: press PGM until the light for the one you want is on. No light lit is your manual setting.
- Program presets: hold PGM and then MODE together for 3 to 5 seconds until light 1 blinks. Press PGM to choose a preset, set its temperature and time as above, repeat for the others, then hold PGM and MODE for 3 to 5 seconds until one beep.
- Counter: press MODE until the counter shows (0000 to 9999). Hold up and down for 3 seconds to reset it.
Sleep, set back, auto off, units and offset
Show the counter, then hold SET then MODE for 3 to 5 seconds. Press MODE to step through the items and hold SET with an arrow to change each one. Hold SET then MODE for 3 to 5 seconds to exit.
| Display | Setting | Range |
|---|---|---|
| 1._XX | Sleep time | OFF to 99 min |
| 2._XXX | Set back temperature | 225 to 300°F |
| 3._XX | Auto shut off | OFF to 99 min |
| 4._X | Unit | F or C |
| 5._XX | User offset | Offset number |
Use the offset only after measuring the platen with a surface probe. Leave the factory code tier (the start-button safety delay) alone.
Watch Insta's video: how to use and operate the Insta 907 dual shuttle press
Embedded from the manufacturer's official channel.
Common questions
Why won't the 907 start when the arm is between the platens?
By design. For operator safety, it only runs when the upper arm is directly over one of the lower platens.
How much air does it need?
30 to 100 psi at the regulator. Don't feed it more than 100 psi.
How do I stop a cycle?
Press DISENGAGE in the center of the panel. The cycle stops immediately and the timer resets.
Are my settings kept when I switch it off?
Yes. The five presets and the manual setting are saved through a power off.
Are there smaller platens?
Insta lists optional 2.5 x 2.5 in accessory platens for the 907. Ask us.
- Insta Model 907 Operation and Maintenance Manual (MNL90000 Rev. L)
- Insta Models 907 and 914 Operation Manual (Rev. E)