Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Pearl Elite and PTM daily flush, cleaning, power down and changing pretreat
At the end of every day, prime the pretreat out of the line, flush with distilled water until it runs clear, take the nozzle out and store it in distilled water, then power down from the Maintenance menu. Pearl says skipping the daily flush can damage many parts and isn't covered by the Elite warranty. Use distilled water only, and on the Elite never let pretreat sit idle for more than 30 minutes.
End of every working day
-
Prime the pretreat out
Open the Maintenance menu. Lift the inlet hose out of the pretreat jug, put a cup under the nozzle and run Pretreatment Auto Prime or hold Pretreatment Manual Prime until the line is nearly clear. You can pour that pretreat back into the jug.
-
Flush with distilled water
Put the hose in a jug of distilled water and run Water Auto Prime or hold Water Manual Prime into the cup. Keep going until no pretreat is left in the lines. Pearl notes this can take several prime cycles or several cups of water.
-
Store the nozzle wet
Twist off the nozzle cap, remove the nozzle and drop it in a small cup of distilled water overnight. Leave distilled water in the lines.
-
Power down from the screen
In the Maintenance menu press Power Down. The cart parks at home, then press OK and switch the power off (O). This saves your settings, cycle count and level meters. If the lines still hold pretreat, the machine won't let you power down.
Pearl warns that skipping the daily flush can damage many components, and the Elite warranty doesn't cover that damage. On the Elite, don't let pretreat sit in the machine for more than 30 minutes: flush it out if you'll be away longer.
Keep the inside clean
Pretreat dries into salt deposits that make the cart and drawer stick. Wipe off the excess with shop towels, then go over the body with an all-purpose cleaner. On the Elite, open the side and front windows, or pull the drawer out with its release tabs. Pearl asks for this after every use on the Elite and after every 10 shirt cycles on the PTM.
Changing between pretreats
The level meters and cost counters work out usage from the prime buttons, so follow this order or the counts drift:
-
Empty the old pretreat
In Maintenance, lift the hose out and prime the line nearly clear into a cup. Pour it back into its jug.
-
Flush with distilled water
Hose into distilled water, then Water Auto Prime or Water Manual Prime until the line is clean. Take the hose out of the water.
-
Switch the selection
Press the Light/Dark Pretreatment Selection icon to choose the pretreat you're changing to, then prime with the pretreatment button until the water is out of the line. Discard the water in the cup.
-
Prime the new pretreat
Put the hose in the new jug, cup under the nozzle, prime and let the pressure build before you spray a shirt.
Keep the level meter honest
The meter assumes a gallon. When you open a full gallon, go to the Stats menu and press Reset Level Meter for that pretreat. Every brand of pretreat flows a little differently, so if the meter hits empty before the jug does, lower the viscosity (tap Cost/Shirt in the Stats menu and move the slider). If it hits empty after, raise it.
Watch Pearl's video: cleaning and purging the spray nozzle
Embedded from the manufacturer's official channel.
Common questions
Can I use tap water to flush?
Pearl's Elite manual says to flush with distilled water only. Use distilled on both models.
The screen won't let me power down. Why?
Pearl blocks the power-down until the fluid lines have been flushed with water. Finish the flush, then press Power Down in the Maintenance menu.
What should I leave in the lines if I'm closed for a week?
Distilled water. Pearl recommends leaving distilled water in the lines for long breaks because it makes the next prime easier. Store the nozzle in distilled water too.
My level meter says empty but the jug isn't. How do I fix it?
Reset the level meter only when you start a full gallon. If the meter runs out before the jug does, lower the viscosity setting (Stats menu, tap Cost/Shirt). If it runs out after, raise it.
How often do I clean inside?
Pearl says after every use on the Elite and after every 10 shirt cycles on the PTM, because dried pretreat leaves salt deposits that stop things moving.
- Pearl Elite Use and Care Guide: flushing, power down, cleaning, changing pretreat and adjustments
- Pearl PTM Use and Care Guide: flushing, power down, cleaning and cost calculations