Support
Machine type
Brand
Pearl Elite and Pearl PTM DTG pretreatment machines

Pearl Elite and PTM spray settings: density, spray length, saved files, Speed Mode, Flexlock and platen height

✓ Reviewed by Jason KimUpdated 2 min readFits: Pearl Elite · Pearl PTM
Short answer

On the Pearl Elite and PTM, open the Settings menu to choose light or dark pretreat, set spray density (20 to 100) with the number or the slider, and set spray length by tapping a quarter of the length area or typing a value. Save each shirt setup as one of 20 files in the Save menu. On the PTM, Speed Mode keeps the cart at the start position between shirts, and Flexlock sprays a 10.5 x 11 inch area for pockets and crests.

The menus at a glance

Menu What it's for
Home Shows the garment type, spray length and density that the next cycle will use; Start/Stop
Settings Light or dark pretreat, spray length, spray density, fan (Elite), Speed Mode and Flexlock (PTM)
Save Up to 20 saved setting files
Maintenance Cart position, priming, power off, Adjust (motor, fan, auto prime timing)
Stats Level meters, cycle count, cost per shirt and per run

Set density and spray length

  1. Open Settings

    Tap the Settings menu icon. Choose Light Garment or Dark Garment for the pretreat you're running.

  2. Set the density

    Press the spray density value and enter a number from 20 to 100, or drag the density slider up or down.

  3. Set the length

    Tap the quarter of the spray length area you want covered, or press the spray length value and type it in.

  4. Check Home before you spray

    Go back to Home. It shows the garment type, length and density the cycle will use. Load the shirt collar toward the back of the Elite (toward the control box on the PTM), tuck the excess under the platen, and press Start. On the Elite, push the drawer all the way in; the gap around the drawer face is there for airflow.

Pearl doesn't publish a density number for each shirt type. Test on a spare shirt of the same fabric and color, then save what works.

Save, open and delete setting files

  1. Save

    Open the Save menu. Your current settings show on the right. Press Save, type a name, and press return.

  2. Open

    Select a file to see its settings, then press Open. The screen switches to Home with those settings loaded.

  3. Delete

    Select the file and press Delete.

PTM only: Speed Mode and Flexlock

  • Speed Mode: in Settings, press the Speed Mode icon. The cart moves to the spray start position before the cycle and returns there afterward, so you can load and spray shirts quickly. Press it again to turn it off.
  • Flexlock: in Settings, press the Flexlock button. The spray length area turns into a square. Attach the optional Flexlock platen attachment. The machine sprays the same density over a 10.5 x 11 inch area, saving pretreat on pocket and crest prints. Press the button again and remove the attachment to go back.

Adjustments Pearl lets you make

  • Platen height (Elite): four thumb nuts under the drawer. Raising the platen pulls the spray edge in and cuts overspray inside the machine; lowering it gives a crisper edge with more overspray. Press the platen down and turn each nut to lower it, turn them the other way to raise it.
  • Motor speed (PTM): Maintenance > Adjust, MOTOR slider, for a lighter or heavier spray. Test by pressing the rail to move the cart. For low densities, Pearl says keep the rail lubricated with silicone spray.
  • Fan timing (Elite): Maintenance > Adjust, FAN slider, to change how long the fan runs after a cycle.
  • Auto prime timing: Maintenance > Adjust, AUTO slider. Raise it if the lines aren't clear of air by the end of an auto prime.
  • Viscosity and costs: in Stats, enter your cost per gallon for light and dark pretreat to see cost per shirt and per run. Press Cost/Shirt to set viscosity so the level meters stay accurate. Reset the level meter only when you start a full gallon.

Spray still uneven or tilted after changing settings? That's usually the nozzle. See our Pearl priming and uneven spray guide, or text a short video to (562) 609-4996.

Watch Pearl's video: digital controls on the Pearl PTM and Elite

More videos

Pearl: how to adjust the Pearl Elite shirt platen height

Embedded from the manufacturer's official channel.

Common questions

What range can I set spray density to?

20 to 100, by typing a value or using the slider in the Settings menu.

How many setups can I save?

Twenty files. Open the Save menu, press Save, name the file and press return.

What do Speed Mode and Flexlock do?

On the PTM, Speed Mode returns the nozzle cart to the spray start position after each cycle so you can load shirts faster. Flexlock, with the optional Flexlock platen attachment, sprays the same density over a 10.5 x 11 inch area.

The pretreat level meter says empty but the jug isn't. Why?

The viscosity setting doesn't match your pretreat. Lower it in the Stats menu (press Cost/Shirt) if the meter empties early; raise it if the meter lags.

My spray is uneven no matter what density I set.

That points to the nozzle, not the settings. Pearl says clean the nozzle with cleaning solution, or replace the nozzle and O-ring.

Sources
Did this fix it?