Prestige R2 Pro and R2 bad nozzle check: how to clear clogs and missing nozzles

✓ Reviewed by Jason KimUpdated 3 min readFits: Prestige R2 Pro · Prestige R2
Short answer

Print a nozzle check first, then work up the ladder: run Fill Ink on the affected head, clean the wiper blade, run two head cleanings and check again. If channels are still missing, warm-wet-cap the head with cleaning solution for 15 minutes and clean again. If that doesn't bring the nozzles back, the cause is usually a damper, the wiper or the capping station seal rather than the head, so send us a photo before you buy a head.

Match your symptom

What you see Most likely cause Go to
A few gaps in one or two colors Partial clog or air Steps 1 to 4
Half a head or more missing Air in the lines or a heavy clog Steps 2 to 5
Same channel still missing after a wet cap Damper, wiper or capping station Step 6
Good check in the morning, nozzles fade during printing Head strike residue, airflow, capping height See the questions below
Nothing prints at all, or odd patterns Electrical or software, not a clog Our error codes guide

Keep the front cover open while you work. If your printer has a front-cover sensor and stops with a cover error, DTF Station's procedure is to tape the L-shaped head lock bracket (the one you removed at setup) in front of the sensor. Take it off when you're done.

Step by step

  1. Print a nozzle check

    Press Menu, go to Head Maintenance > Head Status and press Enter. In Hosonsoft the same test is the Check button. The left head is color (CMYK) and the right head is white. Photograph the result: you'll compare against it after every step.

  2. Run Fill Ink on the affected head

    Press Menu > Head Maintenance > Fill Ink and choose Left Head for color, Right Head for white, or Two Head for both. Start timing when ink visibly flows into the waste bottle, let it run 30 seconds, then press Cancel. This pushes air out of the lines.

  3. Clean the wiper blade

    Press the Left arrow to move the carriage off the capping station. Clean the wiper blade with a foam swab soaked in cleaning solution (a swab, not a lint-free cloth). Press Enter to dock the carriage again.

  4. Run two head cleanings, then check again

    Press the Cleaning button twice, back to back. Advance the film and print another nozzle check. If it isn't complete, go to step 5.

  5. Warm wet cap

    Warm some cleaning solution for about 15 seconds in a microwave so it's warm, not hot. Press the Left arrow to move the carriage away. With a syringe, fill the cap under the affected head without overflowing it. Press Enter so the head sits down on the wet cap, and leave it for 15 minutes. Then run 2 to 3 head cleanings and print a nozzle check. If it improved but isn't perfect, repeat the wet cap once.

    Never boil the solution or use it hot. Boiling solution can delaminate the head. Don't wipe or scrub the head face. There is a stronger pull-through procedure at the cap pump, but done wrong it twists the pump tube or floods the printer, so we only do it with you on a call.

  6. Check the mechanical parts

    If the same channels stay missing, open the capping station compartment and watch a head cleaning at eye level:

    • The wiper blade should touch the head evenly across its width. If it's bent or slanted, it needs straightening or replacing.
    • When you press Enter, the cap should rise and seal against the head, centered under it.
    • A single color that never comes back usually points to a bad damper. See our damper guide.

    Capping station and wiper heights are set in the control software's protected settings. Don't change them on your own.

  7. Send us the evidence

    Text us a photo or short video at (562) 609-4996: the latest nozzle check photo, a 1-minute video of a head cleaning filmed from an angle, and a 30-second video of you pressing Enter a few times so we can see how the head meets the cap. With those three we can usually tell you exactly which part is at fault.

Watch DTF Station's video: unclogging and fixing a poor nozzle check on the Prestige R2

Embedded from the manufacturer's official channel.

Common questions

How good does the nozzle check need to be?

DTF Station's rule is to print when at least 90% of the nozzles are firing. Below that you'll see banding, so clean first.

Should I run a cleaning before the nozzle check?

No. Always check first. Cleaning before you know what's wrong wastes ink and can pull air into the head.

My nozzle check is perfect in the morning but colors drop out after a few prints. Why?

The usual causes are dried residue from an old head strike that the wiper keeps spreading, a fan or air vent blowing on the printer, or a capping station that sits too far from the head. Send us a nozzle check from before the job and one from right after it stops.

Can I use window cleaner or a household cleaner on the caps and wiper?

No. Use DTF Station-approved cleaning solution only. Household cleaners and homemade mixes stain the head, leave debris in the caps and damage the wiper rubber.

Is my print head dead?

Usually not, especially in the first 6 months with no head strike. Rule out dampers, the wiper and the capping station seal first. Heads are wear parts and typically last 1 to 2 years.

Should Auto Clean run during printing?

Keep the during-print Auto Clean set to Close (off) and Pre-Flashing set to Open. That's DTF Station's setting for the R2 Pro, and especially important on the original R2's XP600 heads.

Sources
Did this fix it?