Prestige R2 Pro and R2 dampers: how to tell if one is bad, and how to replace it

✓ Reviewed by Jason KimUpdated 2 min readFits: Prestige R2 Pro · Prestige R2
Short answer

Suspect a damper when one or two channels stay missing after Fill Ink, cleanings and a wet cap, or when you see ink dripping or bubbles at the carriage. Take the damper out, hold it pointing down: if it drips, it's bad. Then pull ink through it with a syringe: steady ink with no bubbles means it's good, while backflow, bubbles or no ink means replace it. Dampers are wear parts that DTF Station expects to be replaced about once a year.

You'll need

  • New damper(s) for your model
  • A syringe
  • Tube clamps (the clips on your ink lines)
  • Paper towels, gloves and a Phillips screwdriver
  • Scissors, if your tubes are stiff

Send us your nozzle check before you start. Pulling dampers without need wears their seals, and we can often tell from the photo whether a damper is really the problem.

Step by step

  1. Take a baseline nozzle check

    Open the front cover and, if your printer has a cover sensor, cover it as described in your setup guide. Run Menu > Head Maintenance > Fill Ink > Two Head for 30 seconds from when ink flows into the waste tank, press Cancel, run two head cleanings, then print and keep a nozzle check (Head Status).

  2. Get to the dampers

    Lift the pinch roller lever and roll the film back out. Open the top lid, press the Left arrow once to undock the carriage, then hold it to bring the carriage to the center. Press the Emergency Stop to power off. Loosen the screws on both sides of the carriage cover and the daughterboard cover and lift both covers off.

  3. Move the white dampers out of the way

    Clamp all the white ink lines and lay paper towels beside the carriage. Remove the diverter (one screw each side) and lift out the white dampers onto the towel.

  4. Test the suspect damper

    Clamp that color's ink line and lift the damper out by its outer plastic frame. Never press the soft side. Hold it pointing down: if ink leaks out, it's bad. Then hold it upright, put a syringe on the bottom and pull slowly. Steady ink flow means it's good. Ink flowing back when you release, no ink, bubbles or a loss of resistance mean it's bad. Reinstall good dampers carefully.

  5. Fit the new damper

    If the tube is soft, pull it straight off the old damper. If it's stiff, cut it straight across just above the damper nozzle. Push the tube fully onto the new damper, release the clamp, and prime it by pulling ink slowly with the syringe from the bottom until ink arrives with no bubbles. A new damper that leaks within a few seconds, sucks ink back, or won't pull ink is faulty: don't install it.

  6. Put it back together

    Seat the new damper, reinstall the white dampers and the diverter, and release every clamp. Refit both covers, release the Emergency Stop and let the carriage dock. Reload the film.

  7. Prime and compare

    Run Fill Ink on Two Head for 30 seconds once ink flows (Right Head only if you replaced a white damper), two head cleanings, and a nozzle check. Compare it with your baseline. Better means the damper was the problem. No change: text us both photos.

Not comfortable opening the carriage? Text us a photo or short video at (562) 609-4996 and we'll walk you through it.

Watch DTF Station's video: replacing a color damper on the Prestige R2 and R2 Pro

Embedded from the manufacturer's official channel.

Common questions

How often should dampers be replaced?

About once a year, along with the inlet filters.

Can I take dampers out to check them whenever I want?

Avoid it. Every removal wears the rubber seal, and a damaged seal makes a good damper go bad. Test only when a channel won't recover.

All my channels are weak. Should I replace every damper?

No. Dampers don't all fail at once. When every channel is affected, the cause is usually the capping station, the environment or settings. Text us first.

Is a little air inside the damper normal?

Yes. A damper normally holds some air with the ink. Bubbles rising into the syringe while you pull, or ink running back when you let go, are the warning signs.

Can I replace a white damper the same way?

The steps are similar, but talk to us before removing white dampers. After replacing one, prime only the white side with Fill Ink on the Right Head.