Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Prestige XL series white ink problems: missing white nozzles, bubbles and the 6-month white service
White ink is heavy and dries faster than color, so it is the first channel to drop out. Keep circulation low in normal use (high circulation pulls air into the line), make sure the white cap is getting cleaning solution, then run a short ink charge on the white head and a cleaning. Hot, dry rooms and fans blowing on the printer are common hidden causes. Every 6 months, the white tank and lines need a full clean-out.
Match your symptom
| What you see | Most likely cause | Go to |
|---|---|---|
| White rows missing on the nozzle check | Dry white cap, settled ink, partial clog | Steps 1 to 3 |
| Bubbles in the white ink tube | Circulation set too high | Step 1 |
| White fades during a job | Airflow on the heads, hot dry room | Step 4 |
| Circulation pump doesn't run | Carriage not parked, or a switch, board or pump fault | Step 5 |
| White still weak after all of the above | Thickened ink in the tank, lines and dampers | 6-month service below |
| Nozzle check fine, but white thin or showing past the edges on transfers | RIP white settings | Our neoStampa guides |
Step by step
-
Set circulation correctly
Run circulation high only briefly in the morning: on the L2 and XL2, knob at 65 for 5 minutes, then down to 10 to 20; on the XL2 Pro, XL3 and XL4, about 40% for 1 minute, then 20% or auto. On the L2 and XL2, run a cleaning before you start circulation. Left high all day, it pulls air into the white line. A good working level is where you can barely hear the pump.
-
Make sure the white cap gets solution
Check that the cleaning solution bottle is at least half full and that the tube to the white cap has no air in it. On the XL2 Pro, XL3 and XL4, move the carriage left and press the wet cap button (on the XL4 it's beside the carriage, behind the left side covers). Solution should flow and fill the white cap. If you can't see any, press it once or twice more. On the L2 and XL2, fill the caps by hand each night.
-
Recover the white head
Return the carriage home. In Pilot, run an ink charge on the white head (H2) for 10 seconds or more, stop it, then run a normal cleaning on H2. Print a nozzle check. Aim for about 95%. If white still won't come back, follow the warm wet cap and ink pull steps in our poor nozzle check guide.
-
Check the room
Hot weather and low humidity are hard on white, and a fan or air conditioner blowing on the printer can dry the white nozzles within minutes of printing. DTF Station recommends 70 to 75°F and 35 to 45% humidity.
-
If the circulation pump won't run
Make sure the carriage is parked in its home position over the caps, then switch circulation on again. If it still doesn't run, the cause is usually the home sensor, the circulation switch or knob, the control board or the pump motor. Contact us and we'll help you narrow it down.
The 6-month white channel service
Over time white ink thickens and builds up in the tank, tubes, dampers and nozzles. Every 6 months, DTF Station has you:
- Close the white valve, disconnect the white tank and its stirrer, and empty it.
- Rinse the tank and stirrer with water until clean, keeping electrical connectors dry, and let everything dry fully.
- Run circulation to push the old ink out of the lines until only air flows.
- Refit the tank, fill it with fresh, well-shaken white ink, circulate, then fill the white head only for about a minute and run two cleanings.
The video above walks through every screw and connector. Watch it in full before starting.
If any connector gets wet, let it dry for 24 hours or wipe it with isopropyl before you power on.
Watch DTF Station's video: 6-month white channel maintenance on the Prestige L2 and XL2
Embedded from the manufacturer's official channel.
Common questions
Why does white go missing when color is fine?
White ink contains heavy pigment that settles and dries faster than color. It needs regular circulation, a wet cap at night, and a room that isn't hot and dry.
I see bubbles in the white ink tube. Is that bad?
Bubbles in the tube usually mean circulation is set too high. Turn it down. Some air inside the damper body is normal; air in the tube above it isn't.
The white looks fine on the nozzle check but thin or patchy on the transfer. Is it the printer?
Often not. White strength and how far the white is pulled in from the edges are set in the RIP. See our neoStampa guides, and check your film and powder.
How should I prepare new white ink before refilling?
Shake the bottle well, then let it sit a few minutes so the bubbles settle before you pour.
Do I have to do the 6-month white service myself?
It is a hands-on job of about an hour or more, with tubes and wiring to disconnect. Watch the video first. If you'd rather not, contact us.
- DTF Station technical documentation
- DTF Station video: Prestige L2 and XL2, 6 Month White Channel Maintenance
- DTF Station video: Prestige XL2 Pro, 6 Month White Channel Maintenance
- DTF Station video: Ink Alarm Feature, Prestige L2 and XL2
- AA support requests about missing white ink and underbase on Prestige printers, 2024 to 2026