Aries 124 water chiller and air compressor: daily checks, refilling the chiller and common problems

✓ Reviewed by Jason KimUpdated 2 min readFits: Aries 124
Short answer

Each morning on the Aries 124, switch on the air compressor (red switch up) and check that the pressure gauge on the left panel rises. The water chiller takes 800 ml of distilled water only. To service it, drain it fully, refill with fresh distilled water, and power it on with the cap off to confirm flow. A chiller leak, a compressor that won't hold air, or a hose that doesn't fit should come to us rather than being patched.

What they do

The Aries 124 has two support units in its cabinets. The water chiller pumps distilled water through the cooling for the UV lamps. The air compressor supplies the air the printer needs, shown on the pressure gauge on the left panel. Both are part of your daily start-up.

Daily start-up

  1. Power on and wait

    Power the printer on and wait for Idle.

  2. Start circulation and air

    Set white ink circulation (dial to 25, press the button), then switch on the air compressor by pulling its red switch up.

  3. Check the gauge

    Look at the air pressure gauge on the left panel. The pressure should rise once the compressor is running. Note where it normally sits so you can spot a change.

Match your symptom

What you see Check
Gauge doesn't rise Compressor switched on (red switch up) and plugged in, hose connected at both ends, regulator not turned all the way down
Compressor runs constantly or won't hold air Listen for a hiss at the hose and fittings. Text us a video. The compressor is a separate unit with its own maker's warranty, so keep its paperwork
Air hose doesn't fit the compressor or the printer Don't force or tape it. Text us a photo of both ends and we'll get you the right fitting
No water moving in the chiller Chiller switched on, water level, tubes not kinked. Then the service below
Water dripping in the cabinet Switch the chiller off and contact us. A leak in the lamp cooling isn't something to patch

Use only distilled water in the chiller, 800 ml. Tap water leaves deposits in the cooling lines.

Chiller service: drain and refill

  1. Switch off and pull it out

    Power the chiller off and slide it out of the cabinet.

  2. Disconnect

    Disconnect the cables by turning the lock nuts. Zip-tie the tubes closed so they don't leak, then disconnect the tubes.

  3. Drain

    Drain all of the old water.

  4. Reconnect and refill

    Reconnect the tubes and cables, then fill with 800 ml of distilled water.

  5. Check flow

    Power the chiller on with the cap off and watch that the water is flowing. Then close the cap.

When you're not printing for a few days

If you print every day, power off at night. If you'll be back in 2 to 3 days, DTF Station leaves the printer on but turns off the air purifier, chiller, heating, vacuum and take-up motor. For about a week, leave everything on and press the emergency stop, which keeps circulation and stirring going.

Not sure what pressure your regulator should be set to? Text us before changing it, and we'll confirm the setting for your unit. Text us a photo or short video at (562) 609-4996.

Watch DTF Station assemble the Aries 124, including the chiller and compressor

Embedded from the manufacturer's official channel.

Common questions

What water goes in the Aries 124 chiller?

Distilled water only, 800 ml.

How do I know the chiller is working?

After filling, power it on with the cap off and watch for water flow, then close the cap.

The air pressure gauge doesn't move. What do I check?

That the compressor's red switch is up, it's plugged in, the hose is connected at both ends and the regulator isn't turned all the way down. Then text us a video.

Should the chiller stay on overnight?

Daily users power the printer off at night. For a 2 to 3 day break, DTF Station turns the chiller off along with the purifier, heating, vacuum and take-up motor.

The air hose that came with my printer doesn't fit. What now?

Don't force or tape it. Send us a photo of both ends and we'll sort out the right fitting.