Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Aries 124 water chiller and air compressor: daily checks, refilling the chiller and common problems
Each morning on the Aries 124, switch on the air compressor (red switch up) and check that the pressure gauge on the left panel rises. The water chiller takes 800 ml of distilled water only. To service it, drain it fully, refill with fresh distilled water, and power it on with the cap off to confirm flow. A chiller leak, a compressor that won't hold air, or a hose that doesn't fit should come to us rather than being patched.
What they do
The Aries 124 has two support units in its cabinets. The water chiller pumps distilled water through the cooling for the UV lamps. The air compressor supplies the air the printer needs, shown on the pressure gauge on the left panel. Both are part of your daily start-up.
Daily start-up
-
Power on and wait
Power the printer on and wait for Idle.
-
Start circulation and air
Set white ink circulation (dial to 25, press the button), then switch on the air compressor by pulling its red switch up.
-
Check the gauge
Look at the air pressure gauge on the left panel. The pressure should rise once the compressor is running. Note where it normally sits so you can spot a change.
Match your symptom
| What you see | Check |
|---|---|
| Gauge doesn't rise | Compressor switched on (red switch up) and plugged in, hose connected at both ends, regulator not turned all the way down |
| Compressor runs constantly or won't hold air | Listen for a hiss at the hose and fittings. Text us a video. The compressor is a separate unit with its own maker's warranty, so keep its paperwork |
| Air hose doesn't fit the compressor or the printer | Don't force or tape it. Text us a photo of both ends and we'll get you the right fitting |
| No water moving in the chiller | Chiller switched on, water level, tubes not kinked. Then the service below |
| Water dripping in the cabinet | Switch the chiller off and contact us. A leak in the lamp cooling isn't something to patch |
Use only distilled water in the chiller, 800 ml. Tap water leaves deposits in the cooling lines.
Chiller service: drain and refill
-
Switch off and pull it out
Power the chiller off and slide it out of the cabinet.
-
Disconnect
Disconnect the cables by turning the lock nuts. Zip-tie the tubes closed so they don't leak, then disconnect the tubes.
-
Drain
Drain all of the old water.
-
Reconnect and refill
Reconnect the tubes and cables, then fill with 800 ml of distilled water.
-
Check flow
Power the chiller on with the cap off and watch that the water is flowing. Then close the cap.
When you're not printing for a few days
If you print every day, power off at night. If you'll be back in 2 to 3 days, DTF Station leaves the printer on but turns off the air purifier, chiller, heating, vacuum and take-up motor. For about a week, leave everything on and press the emergency stop, which keeps circulation and stirring going.
Not sure what pressure your regulator should be set to? Text us before changing it, and we'll confirm the setting for your unit. Text us a photo or short video at (562) 609-4996.
Watch DTF Station assemble the Aries 124, including the chiller and compressor
Embedded from the manufacturer's official channel.
Common questions
What water goes in the Aries 124 chiller?
Distilled water only, 800 ml.
How do I know the chiller is working?
After filling, power it on with the cap off and watch for water flow, then close the cap.
The air pressure gauge doesn't move. What do I check?
That the compressor's red switch is up, it's plugged in, the hose is connected at both ends and the regulator isn't turned all the way down. Then text us a video.
Should the chiller stay on overnight?
Daily users power the printer off at night. For a 2 to 3 day break, DTF Station turns the chiller off along with the purifier, heating, vacuum and take-up motor.
The air hose that came with my printer doesn't fit. What now?
Don't force or tape it. Send us a photo of both ends and we'll sort out the right fitting.
- Aries 124: Assembly (DTF Station video)
- DTF Station technical documentation
- AA support requests about the Aries 124 chiller and air compressor, 2024 to 2026