Support
Machine type
Brand
Summa S Class 3 vinyl cutter

Connecting a Summa S Class 3 or S One cutter to your computer: USB, Ethernet, Wi-Fi and GoSign

✓ Reviewed by Jason KimUpdated 3 min readFits: S Class 3 (D, T, TC) · S One (D60 to D160)
Short answer

On Windows, install Summa's USB driver before you plug the cutter in, with an administrator account and UAC set to its lowest level. On a Mac no driver is needed, because the cutting software carries it. For a network connection, use a shielded CAT6 cable and give the cutter a fixed IP address in Configuration > Ethernet, then reboot it. Current S Class 3 and S One cutters are meant to be driven from Summa GoSign V4.

Match your symptom

What you see Most likely cause Go to
Windows doesn't recognize the cutter on USB Driver not installed first, or no admin rights Step 2
Software can't find a network cutter IP address changed, or wrong address in the software Step 3
Message says Wi-Fi isn't available in your region Wi-Fi isn't offered there Step 4
Wi-Fi menu asks for a code Wi-Fi not activated yet Step 4
Jobs go nowhere with two cables plugged in The other port took the connection Step 1

Step by step

  1. Pick one connection

    The S Class 3 and S One both have USB and Ethernet ports, and Wi-Fi as an option. If USB and Ethernet are both plugged in, the port that receives data first stays active and the other one is shut off. Pick one connection and stick with it, so you always know where your jobs are going.

  2. USB on Windows: driver first, cable second

    Log in with an administrator account and set User Account Control to its lowest level. Switch the cutter off. Download and install the USB driver for your model from Summa's software and firmware page. Then connect the cable (USB A on the computer, USB B on the cutter, 5 m or 16 ft at most), switch the cutter on and let Windows finish installing the device. Restart the computer.

    If you plugged the cutter in before running the installer, leave the cutter connected and switched on and run the installer then. Windows should detect the cutter and pick the right driver.

    On a Mac, current cutting software does not need a separate driver.

  3. Ethernet: use a fixed IP address

    Use a shielded CAT6 cable. Ask whoever runs your network for a free address and the subnet mask. Summa recommends a fixed (static) address. On the touch screen open the menu, scroll to Configuration > Ethernet, set DHCP to Off, then enter the IPv4 address and the Subnet mask, confirm each one and reboot the cutter. Enter the same address in your cutting software.

    If you prefer DHCP, set it to On and reboot. The address the network assigns shows on the cutter's main screen. It can change if the cutter is unused for longer than the DHCP lease time, which is the usual reason a network cutter suddenly goes missing.

  4. Wi-Fi: activate it first

    Wi-Fi is switched off from the factory and is only offered in some regions (the S One manual names Europe, the US and Canada). To turn it on, tap the machine information button to read the serial number, register the cutter on Summa's product registration page, and enter the 6-digit activation code you receive under Configuration > Wi-Fi. Keep the email with the code. The same code unlocks the OPOS barcode feature. Then choose your network, enter the password, and set a fixed IP address the same way as for Ethernet if your network allows it.

  5. Install the software

    Summa's own software for these cutters:

    • GoSign V4: Summa's cutting and print-and-cut software for the S Class 3 (firmware MD9987 revision 22 or later) and S One cutters from 2019 or later (firmware MD9986 revision 20.4 or later). Windows 10 or 11, Professional or Enterprise, 64-bit.
    • GoSign Tools: plug-ins for CorelDRAW, Illustrator and Inkscape that send jobs to GoSign.
    • MacSign: Illustrator plug-ins for cutting straight from a Mac. It is registered with your cutter's serial number.
    • Summa Cutter Control: Windows utility for changing cutter parameters, saving user configurations and running the OPOS barcode server.

    The firmware revision is shown on the machine information screen. If your cutter is older than GoSign V4 needs, contact us before you update firmware.

  6. Send a test job

    Load media, set your knife (see the knife guide for your model), then send a small cut from GoSign. If nothing arrives, check that the cutter is online on its main screen. Touching the menu takes the cutter offline and pauses it until you return to the main screen.

Still not connecting?

Text us at (562) 609-4996 with your cutter model, firmware revision, how it's connected and a photo of the cutter's main screen, and we'll walk you through it.

Watch Summa's video: connecting the S3 cutter to GoSign

More videos

How to Connect Your Summa S1 Cutter to GoSign
Summa S Class 3 Roll Cutter Complete Installation

Embedded from the manufacturer's official channel.

Common questions

Can I use USB and Ethernet at the same time?

Both can be plugged in, but only one works at a time. Whichever port receives data first stays active and the other is switched off.

My cutter worked yesterday over the network and now GoSign can't find it. Why?

If the cutter gets its address from a DHCP server, the address can change when the cutter sits unused longer than the server's lease time. Check the IP address on the cutter's main screen and update it in your software, or set a fixed IP address on the cutter.

Which GoSign version do I need?

Summa says GoSign V4 is for the S Class 3 with firmware MD9987 revision 22 or later, and for S One cutters from 2019 or later with firmware MD9986 revision 20.4 or later. GoSign V3 still runs these cutters, but Summa strongly recommends moving to V4. Both need Windows Professional or Enterprise, not Home.

Does Wi-Fi work out of the box?

No. Wi-Fi is an option that is switched on with an activation code from Summa's product registration page, and it is only offered in some regions. The same code switches on the OPOS barcode feature.

Can I cut without a computer?

The S Class 3 can cut a file straight from a FAT32 USB flash drive through Actions > Open File. Summa says it only accepts cut files made by cutter software: .plt, .dmpl, .hpgl or .summa1.

Did this fix it?