Support
Machine type
Brand
Summa S Class 3 vinyl cutter

Summa S Class 3 or S One won't power on: power checks and replacing the fuses

✓ Reviewed by Jason KimUpdated 2 min readFits: S Class 3 (D, T, TC) · S One (D60 to D160)
Short answer

First make sure the screen isn't just asleep: tap it once. Then check the rocker switch on the rear power entry module, the cord and a grounded outlet. If there is still nothing, unplug the cutter and check the two fuses in the power entry module. Summa specifies T2A 250V fuses only. If new fuses blow again, or the cutter stays dead with good fuses, stop and contact us.

Match your symptom

What you see Most likely cause Go to
Black screen with a Summa logo Screen saver Step 1
Nothing at all, no light, no screen Switch, cord, outlet or fuses Steps 2 to 4
New fuses blow again Internal fault Contact us
Powers on but behaves oddly afterward Needs a check Step 5

Step by step

  1. Rule out the screen saver

    After a while without use the touch screen goes blank and shows the Summa logo. The S Class 3 may show a tip instead, for example when the pinch rollers are left down. Tap the screen once. On the S Class 3, the light bar in the top cover also tells you the machine is on: blue when idle, green while working, red when there is an error that needs attention.

  2. Check the switch and cord

    The power switch is the I/O rocker on the power entry module at the back. Switch it off, check the cord is pushed fully into the power entry module and into a properly grounded wall socket, then switch it on. When it powers up, the touch screen comes on and the cutter initializes. If media is loaded, it measures and loads it.

    Don't use a cord that is visibly damaged, and always unplug by the plug, not the cable.

  3. Try another outlet

    Plug something else into the same outlet, or plug the cutter into a different grounded outlet. Skip power strips and extension leads while you test.

  4. Check and replace the fuses

    Summa lets owners change the fuses. Disconnect the cutter completely from power first. Gently pry the release clips of the fuse holder in the power entry module until it pops out, take the holder out, and remove the two fuses. Fit new fuses of exactly the same type and rating, then click the holder back in.

    Summa's rating is T2A 250V (time-delay, 2 amp). A higher-rated fuse removes the fire protection the fuse is there for.

  5. Run the confidence test

    Once it powers up, load a sheet of at least A3 or B size and run Actions > Confidence test. It is Summa's quick electrical and mechanical check, and it always cuts on the left side of the loaded media. A clean result means the cutter is working.

When to stop and call us

  • New fuses blow straight away or after a short time.
  • Good fuses, good outlet, and still no screen or light.
  • You smell burning or see damage at the power entry module.

These point to the power supply or the mainboard, which is a job for a technician. Unplug the cutter and text us at (562) 609-4996 with the model and serial number from the back label.

Watch Summa's video: S Class 3 installation, including power-up

Embedded from the manufacturer's official channel.

Common questions

The screen is black with a Summa logo. Is it broken?

Probably not. Both cutters have a screen saver that blanks the screen and shows the Summa logo. Tap the screen once to wake it.

What fuses does it take?

Summa lists T2AH 250V for the S Class 3 and T2A H250V for the S One. That is a 2 amp, time-delay fuse. Never fit a higher rating.

I replaced the fuses and they blew again. What now?

Don't keep replacing them. A fuse that keeps blowing means something inside is faulty. Unplug the cutter and contact us.

How do I check the cutter works properly after a power problem?

Load a sheet of at least A3 or B size and run Actions > Confidence test. It is Summa's quick electrical and mechanical check and cuts on the left side of the media.

Sources
Did this fix it?