Machine type
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
Epson SureColor G6070 DTF printer
Mimaki TxF300-1600
Mimaki TxF330-800
STS XPD-924D DTF Printer (Mutoh)
STS VJ-628D DTF Printer (Mutoh)
DTF Station Vega S17
STS XpertJet 1682D (XPJ-1682D) 64 inch DTF Printer
STS XPD-724 DTF Printer (Mutoh)
Hotronix Fusion IQ, Air Fusion IQ and Dual Air Fusion IQ
Geo Knight DK20S and DK20SP Digital Knight Swing-Away Presses
DTF Station Maxima and Proxima Dual Heat Presses
Hotronix Auto Open Clam and Hover Heat Press
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
Insta 718, 728 and 828 Automatic Swing-Away Heat Presses
DTF Station Prisma Sentry Heat Press
Geo Knight DC16 and DC16AP Digital Combo Swing-Away Presses
Geo Knight DK Digital Clamshell Presses: DK20, DK16, DKA Auto, DK8 Label and DK7 Cap
Hotronix Auto Open Cap Press and 360 IQ Hat Press
Hotronix Craft Heat Press 9 x 12
Hotronix Mighty Mug Heat Press
Insta 256 and 288 Manual Swing-Away Heat Presses
Insta 907 Dual Station Shuttle Label Heat Press
Viper MAXX pretreatment machine
Ecofreen Mister-T2 and Mister-T2 Pro pretreatment machines
Pearl Elite and Pearl PTM DTG pretreatment machines
Viper XPT-1000 pretreatment machine
Lawson Silver-Jet and Silver-Jet V2 DTG Pretreat Sprayers
Lawson Zoom-AE DTG pretreatment machine
Viper MINI handheld DTG pretreatment machine
Brand
Prestige XL series (L2, XL2, XL2 Pro, XL3, XL4)
DTF Station Prestige R2 Pro
DTF Station Prestige R1
DTF Station Prestige R2 (original)
Prestige X6
DTF Station Prestige A4
DTF Station Prestige A3+ and A3+ R
DTF Station Aries 124 UV DTF printer
Miro DTF Powder Shakers: Miro 13 Max, 16, 24 and 36
DTF Station Aries 213 and Aries 113 UV DTF printers
Seismo L16R and L24R DTF Powder Shaker and Dryer
Phoenix Air 16x20 DTF Curing Oven
DTF Station Maxima and Proxima Dual Heat Presses
DTF Station Prisma Auto Heat Press
DTF Station Prisma Dual Heat Press
DTF Station Prisma Swing Heat Press
DTF Station Vega S17
DTF Station Prisma Sentry Heat Press
DTF Station Seismo V36R DTF Powder Shaker and Dryer
DTF Station Arc 127 automatic cutter for DTF and UV DTF film
Epson SureColor F2100
Epson SureColor G6070 DTF printer
Epson SureColor F2270
Epson SureColor F3070
Epson SureColor F570
Epson SureColor F170
Epson SureColor F6470 and F6470H
Epson SureColor F6370
Epson SureColor F7200
Epson SureColor P-Series photo printers (P700, P900, P6570, P8570)
Epson SureColor T-Series CAD and technical printers
Epson SureColor S-Series (S40600, S60600, S80600)
Viper XPT-1000 and MAXX daily and weekly cleaning: Viper's routine
Flush every Viper at the end of every working day. On the XPT-1000, purge cleaning solution for 10 to 15 seconds, then water for 15 to 20 seconds. On the MAXX, purge out the pretreat, purge water for 30 seconds and leave only water in the machine. Then do the deeper line clean every two weeks on the XPT-1000, or weekly on the MAXX, which also cleans and oils the rails.
Viper XPT-1000
The XPT-1000 has three supply tubes on the back: pretreat (red button), water (blue) and cleaning solution (green).
Daily, at the end of the day
-
Catch the purge
Put the purge bottle under the spray nozzle.
-
Purge cleaning solution
Hold the green CLEANING button for 10 to 15 seconds.
-
Purge water
Hold the blue WATER button for 15 to 20 seconds.
-
Wipe down
Wipe any exposed pretreat off the machine with cleaning solution. You don't need to remove the spray tip unless it isn't spraying evenly.
Every two weeks: clean the pretreat line
The daily purge only cleans the cleaning and water lines. This routine pushes cleaner and water through the pretreat line itself.
-
Swap cleaner into the pretreat input
Press the ring on the quick-connect to release the pretreat supply tube, and release the cleaning tube the same way. Push the cleaning tube firmly into the pretreat input.
-
Purge it
With the purge container under the nozzle, hold the red PRETREATMENT button for 15 seconds.
-
Repeat with water
Move the cleaning tube back. Plug the water tube into the pretreat input and hold the red button another 15 seconds.
-
Put every tube back
Return the water tube to the water input and the pretreat tube to the pretreat input. Check the filter on the end of each supply tube and wipe off any debris with your finger.
Viper MAXX
The MAXX has one fluid supply tube, which you move between jugs, and a Purge button on the side.
Daily
-
Empty the pretreat
Lift the supply line out of the pretreat and purge for 10 seconds to empty the line.
-
Flush with water
Put the supply line in a jug of water (hot tap water, not boiling, works best) and purge for 30 seconds.
-
Leave water in it
Leave only water in the machine overnight. If your water is hard, use distilled water for flushing and for leaving in the machine.
Weekly
-
Empty and flush
Do daily steps 1 and 2.
-
Purge cleaning solution
Put the supply line in Image Armor cleaning solution and purge for 30 seconds.
-
Flush the cleaner out
Run the full daily routine again so only water is left inside.
Never leave pretreat or cleaning solution sitting in the MAXX.
-
Clean and oil the rails
Disconnect the power. Wipe the rails with rubbing or denatured alcohol. When they need it, oil them with 3-in-1 original oil or a lightweight slide oil only.
Good habits on both machines
- Keep the bellows installed and the lids on so mist doesn't build up inside.
- On the MAXX, leave Auto Clean on during the day. It briefly purges the tip while the machine is idle so it stays wet.
- After any repair or deep clean, do a test spray with water before you load pretreat.
- If a machine breaks down, flush and clean it as well as you can before it sits, so pretreat doesn't harden inside while you wait for parts.
Watch Viper's video: cleaning and oiling the MAXX rail systems
Embedded from the manufacturer's official channel.
Common questions
Can I leave cleaning solution in the machine overnight?
Not in the MAXX. Viper says to leave only water in it, never pretreat or cleaning solution. The XPT-1000's daily routine ends with a water purge as well.
Can I use tap water?
Yes, Viper says hot tap water (not boiling) clears pretreat better than room-temperature water. If your water is hard, use distilled.
What oil goes on the MAXX rails?
Only 3-in-1 original oil or a lightweight slide oil. Viper warns that grease or other lubricants slow the spray and can make the carriage bind. Clean the rails with rubbing or denatured alcohol first.
What cleaning solution do I use?
The machines ship with Image Armor cleaning solution, which is what Viper's instructions call for. Wipe the body, spray chamber and platen with it too.
My machine sat for a week without being flushed. What now?
Run the weekly clean first. If the pattern is still bad, clean the spray tip and solenoids as in our guide to a Viper that won't spray, or text us at (562) 609-4996.